6ES7212-1AF40-0XB0 Siemens CPU 1212 FC Original Brand New

 468.95

  • 6ES7212-1AF40-0XB0
  • SIMATIC S7-1200
  • CPU 1212 FC
  • Fail-safe compact CPU
  • For standard or safety operating mode
  • PLe (ISO 13849-1)
  • SIL 3 (IEC 61508)
  • DC/DC/DC
  • PROFINET port
  • 8 digital inputs 24 V DC
  • 6 digital outputs relay 24 V DC/0.5 A
  • 2 analogue inputs 0–10 V DC
  • Power supply: 20.4–28.8 V DC
  • Programme/data storage: 100 KB
  • Programming package from STEP 7 V14For safety operating mode
  • You need an installed STEP 7 Safety licence.***A return is only possible in unopened condition***

Available on backorder

Siemens CPU 1212 FC – 6ES7212-1AF40-0XB0

Overview

6ES7212-1AF40-0XB0

The fail-safe SIMATIC S7-1200 Controllers are based on the S71200 standard CPUs and offer additional safety-related functions.

They can be used for safety-oriented tasks according to IEC 61508 up to SIL 3 and ISO 13849-1 up to PL e.

Safety-related programs are created in the TIA Portal. The STEP 7 Safety engineering tool offers commands, operations and blocks for safety-related programs in the LAD and FBD languages. To this end, there is a library with pre-configured, TÜV-approved blocks for safety-related functions.

  • Standard controller with integrated safety functions:
    • Standardized and convenient diagnostic functions for standard and safety
    • Uniform symbols, data consistency, …
  • Modular system with scalable range of CPUs and expandable I/O quantity structure:
    • One engineering for standard and fail-safe automation
    • Use of the standard I/O modules together with the fail-safe I/O modules in the central system
    • Integrated standard PROFINET functionalities for PROFINET controllers and PROFINET iDevice services
    • Connection of distributed standard I/O via field bus such as PROFINET or PROFIBUS
    • F-library certified by the German Technical Inspectorate (TÜV) for all common safety functions
    • Free programming of the safety logic using FBD and LAD
    • Standard-compliant printout of the F-program
  • One integrated engineering for both standard and safety from S7-1200 to S7-300/400/1500 and WinAC RTX F:
    • STEP 7 Safety Basic for easy engineering of the CPU Siemens 1212FC
    • STEP 7 Safety Advanced for the entire fail-safe SIMATIC S7 portfolio
  • Integrated system diagnosis of the CPUs, for standard and safety:
    • Consistent plain text display of system diagnostic information in the TIA Portal, HMI and web server
    • Messages are updated even if the CPU is in STOP state
    • System diagnostics integrated in the CPU firmware. Configuration by user not required
    • The diagnostics is automatically updated on configuration changes.
  • 2 fail-safe compact controllers with graded performances in the versions DC/DC/DC and DC/DC/relay

Application

6ES7212-1AF40-0XB0

SIMATIC S7-1200 is the ideal controller for local and distributed automation solutions with safety requirements in the central configuration.

Via the engineering, the fail-safe SIMATIC S7-1200 controller makes preassembled, tested and TÜV/German Technical Inspectorate-certified blocks available for implementing all common safety functions, such as EMERGENCY STOP or protective door monitoring, with or without interlocking.

  • CPU 1212FC:
    The ideal compact solution for standard and fail-safe applications
  • CPU 1214 FC:
    The compact CPU for standard and fail-safe applications
  • CPU 1215 FC:
    The compact CPU with two PROFINET ports for standard and fail-safe applications

Design

Mechanical features

  • Horizontal or vertical mounting on DIN rail or direct mounting in the cabinet using integral drill holes (not horizontal).
  • Terminal block for independent wiring for all CPUs and associated components.

Technical specifications

6ES72121AF400XB0

Siemens 6ES7212 1AF40 0XB0, SIMATIC S71200, CPU 1212 FC, compact CPU, DC/DC/DC, onboard I/O: 8 DI 24 V DC; 6 DO 24 V DC; 2 AI 0-10 V DC, Power supply: DC 20.4-28.8V DC, Program/data memory 100 KB

Download

DataSheet in PDF

Weight 0.340 kg
Dimensions 10.60 × 10.80 × 8.60 mm
Brand

SIEMENS

Product type designation

CPU 1212FC DC/DC/DC

Firmware version

V4.5

● Programming package

STEP 7 V17 or higher

Rated value (DC)

● 24 V DC

Yes

permissible range, lower limit (DC)

20.4 V

permissible range, upper limit (DC)

28.8 V

Reverse polarity protection

Yes

● permissible range, lower limit (DC)

20.4 V

● permissible range, upper limit (DC)

28.8 V

Current consumption (rated value)

400 mA; CPU only

Current consumption, max.

1 200 mA; CPU with all expansion modules

Inrush current, max.

12 A; at 28.8 V DC

I²t

0.5 A²·s

for backplane bus (5 V DC), max.

1 000 mA; Max. 5 V DC for SM and CM

● 24 V

L+ minus 4 V DC min.

Power loss, typ.

9 W

● expandable

No

● integrated

2 Mbyte

● Plug-in (SIMATIC Memory Card), max.

with SIMATIC memory card

● maintenance-free

Yes

● without battery

Yes

for bit operations, typ.

0.08 µs; / instruction

for word operations, typ.

1.7 µs; / instruction

for floating point arithmetic, typ.

2.3 µs; / instruction

Number of blocks (total)

DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used

● Number, max.

Limited only by RAM for code

Retentive data area (incl. timers, counters, flags), max.

14 kbyte

● Size, max.

4 kbyte; Size of bit memory address area

● per priority class, max.

16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB

● Inputs, adjustable

1 kbyte

● Outputs, adjustable

1 kbyte

Number of modules per system, max.

3 comm. modules, 1 signal board, 2 signal modules

● Hardware clock (real-time)

Yes

● Backup time

480 h; Typical

● Deviation per day, max.

60 s/month at 25 °C

Number of digital inputs

8; Integrated

● of which inputs usable for technological functions

4; HSC (High Speed Counting)

Source/sink input

Yes

— up to 40 °C, max.

8

● Rated value (DC)

24 V

● for signal "0"

5 V DC at 1 mA

● for signal "1"

15 V DC at 2.5 mA

— at "0" to "1", min.

0.2 ms

— at "0" to "1", max.

12.8 ms

— parameterizable

Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz

Number of digital outputs

6

● of which high-speed outputs

4; 100 kHz Pulse Train Output

Limitation of inductive shutdown voltage to

L+ (-48 V)

● with resistive load, max.

0.5 A

● on lamp load, max.

5 W

● for signal "0", max.

0.1 V; with 10 kOhm load

● for signal "1", min.

20 V

● for signal "1" rated value

0.5 A

● for signal "0" residual current, max.

0.1 mA

● "0" to "1", max.

1 µs

● "1" to "0", max.

5 µs

● of the pulse outputs, with resistive load, max.

100 kHz

● Number of relay outputs

0

● unshielded, max.

150 m

Number of analog inputs

2

● Voltage

Yes

● 0 to +10 V

Yes

— Input resistance (0 to 10 V)

≥100k ohms

● shielded, max.

100 m; twisted and shielded

Number of analog outputs

0

● Resolution with overrange (bit including sign), max.

10 bit

● Integration time, parameterizable

Yes

● Conversion time (per channel)

625 µs

● 2-wire sensor

Yes

Interface type

PROFINET

Isolated

Yes

automatic detection of transmission rate

Yes

Autonegotiation

Yes

Autocrossing

Yes

● RJ 45 (Ethernet)

Yes

● Number of ports

1

● integrated switch

No

● PROFINET IO Controller

Yes

● PROFINET IO Device

Yes

● SIMATIC communication

Yes

● Open IE communication

Yes; Optionally also encrypted

● Web server

Yes

● Media redundancy

No

● Transmission rate, max.

100 Mbit/s

— Prioritized startup

Yes

— Number of IO devices with prioritized startup, max.

16

— Number of connectable IO Devices, max.

16

— Number of connectable IO Devices for RT, max.

16

— of which in line, max.

16

— Activation/deactivation of IO Devices

Yes

— Number of IO Devices that can be simultaneously activated/deactivated, max.

8

— Updating time

The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.

— PG/OP communication

Yes; encryption with TLS V1.3 pre-selected

— Isochronous mode

No

— IRT

No

— PROFIenergy

Yes

— Shared device

Yes

— Number of IO Controllers with shared device, max.

2

Supports protocol for PROFINET IO

Yes

PROFIsafe

Yes

PROFIBUS

Yes; CM 1243-5 (master) or CM 1242-5 (slave) required

OPC UA

Yes; OPC UA Server

AS-Interface

Yes; CM 1243-2 required

● DHCP

No

● SNMP

Yes

● DCP

Yes

● LLDP

Yes

— MRP

No

— MRPD

No

● TCP/IP

Yes

● ISO-on-TCP (RFC1006)

Yes

● UDP

Yes

— Data length, max.

1 472 byte

● User-defined websites

Yes

● Runtime license required

Yes; "Basic" license required

● OPC UA Server

Yes; data access (read, write, subscribe), method call, runtime license required

— Application authentication

Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

— User authentication

"anonymous" or by user name & password

— Number of sessions, max.

10

— Number of subscriptions per session, max.

50

— Sampling interval, min.

100 ms

— Publishing interval, min.

200 ms

— Number of server methods, max.

20

— Number of monitored items, max.

1 000

— Number of server interfaces, max.

2

— Number of nodes for user-defined server interfaces, max.

2 000

● MODBUS

Yes

● supported

Yes

● as server

Yes

● as client

Yes

● User data per job, max.

See online help (S7 communication, user data size)

● overall

PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max

● Status/control variable

Yes

● Variables

inputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters

● Forcing

Yes; peripheral inputs/outputs (without fail-safe)

● present

Yes

● Number of configurable Traces

2

● Memory size per trace, max.

512 kbyte

● RUN/STOP LED

Yes

● ERROR LED

Yes

● MAINT LED

Yes

Counter

● Number of counters

6

● Counting frequency, max.

100 kHz

Frequency measurement

Yes

controlled positioning

Yes

Number of position-controlled positioning axes, max.

8

Number of positioning axes via pulse-direction interface

Up to 4 with SB 1222

PID controller

Yes

Number of alarm inputs

4

Number of pulse outputs

4

Limit frequency (pulse)

100 kHz

● Potential separation digital inputs

No

● Potential separation digital outputs

Yes

● between the channels

No

● between the channels, in groups of

1

● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2

Yes

— Test voltage at air discharge

8 kV

— Test voltage at contact discharge

6 kV

● Interference immunity on supply lines acc. to IEC 61000-4-4

Yes

● Interference immunity on signal cables acc. to IEC 61000-4-4

Yes

● Interference immunity on supply lines acc. to IEC 61000-4-5

Yes

● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6

Yes

● Limit class A, for use in industrial areas

Yes; Group 1

● Limit class B, for use in residential areas

Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011

IP degree of protection

IP20

CE mark

Yes

UL approval

Yes

cULus

Yes

FM approval

Yes

RCM (formerly C-TICK)

Yes

KC approval

Yes

Marine approval

Yes

● Performance level according to ISO 13849-1

PLe

● SIL acc. to IEC 61508

SIL 3

● Fall height, max.

0.3 m; five times, in product package

● horizontal installation, min.

0 °C

● horizontal installation, max.

55 °C

● vertical installation, min.

0 °C

● vertical installation, max.

45 °C

● min.

-40 °C

● max.

70 °C

● Operation, min.

795 hPa

● Storage/transport, min.

660 hPa

● Storage/transport, max.

1 080 hPa

● Installation altitude, min.

-1 000 m

● Installation altitude, max.

5 000 m; Restrictions for installation altitudes > 2 000 m, see manual

● Operation, max.

95 %; no condensation

● Vibration resistance during operation acc. to IEC 60068-2-6

2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail

● Operation, tested according to IEC 60068-2-6

Yes

● tested according to IEC 60068-2-27

Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms

● SO2 at RH < 60% without condensation

S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free

— LAD

Yes; incl. failsafe

— FBD

Yes; incl. failsafe

— SCL

Yes

● User program protection/password protection

Yes

● Copy protection

Yes

● Block protection

Yes

● protection of confidential configuration data

Yes

● Protection level: Write protection

Yes

● Protection level: Read/write protection

Yes

● Protection level: Complete protection

Yes

● adjustable

Yes

Width

90 mm

Height

100 mm

Depth

75 mm

Weight, approx.

370 g