Siemens SINAMICS G120 CU240E-2 F Control Unit E-type Safety Integrated STO F-type SS1 6SL3244-0BB13-1BA1
Overview
CU230P‑2 Control Units
CU230P‑2 PN Control Unit
The Control Unit performs closed-loop control functions for the converter.
The CU230P-2 Control Units are designed for drives with integrated technological functions for pump, fan and compressor applications.
The I/O interface, the fieldbus interfaces and the additional software functions optimally support these applications. The integration of technological functions is a significant differentiating feature to the other Control Units of the SINAMICSÂ G120 converter family.
The CU230P-2 Control Units can be operated with the following Power Modules:
- PM240‑2
- PM250
Typical, integrated HVAC/HLK functions
- Linear and quadratic torque characteristic for fluid flow and positive displacement machines
- ECO mode for additional energy saving in V/f control mode
- 2 analog inputs (current/voltage can be selected) to directly connect pressure/level sensors
- 2 additional analog inputs to connect Pt1000/LG‑Ni1000/DIN‑Ni1000 temperature sensors
- Direct control of valves and flaps using two 230 V AC relays
- Automatic restart
- Flying restart
- Skip frequencies
- Hibernation mode
- Load check function to monitor belts and flow
- Cascade connection
- 4 integrated PID controllers (e.g. for temperature, pressure, air quality, level)
- Multi-zone controller
- Essential service mode
- Real time clock with three time generators
IOP‑2 wizards for special applications
- Pumps: Positive displacement (constant load torque) and centrifugal pumps (square load torque) with and without PID controller
- Fans: Radial and axial fans (square load torque) with and without PID controller
- Compressors: Positive displacement (constant load torque) and fluid flow machines (square load torque) with and without PID controller
Control Unit CU240E‑2
CU240E‑2 DP‑F Control Unit
The Control Unit performs closed-loop control functions for the converter.
The CU240E‑2 Control Unit is designed as standard Control Unit for all of the usual applications involving V/f or vector control.
- CU240E-2 series with standard I/O quantity structure and integrated safety technology
The CU240E‑2 Control Unit can be combined with the following Power Modules:
- PM240‑2
- PM250
Safety Integrated Functions
The Safety Integrated Function “Safe Torque Off” (STO) (certified according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3) is already integrated into the basic versions of the CU240E‑2 series (CU240E‑2, CU240E‑2 DP, CU240E‑2 PN).
With the fail-safe variants of the CU240E-2 series (CU240E‑2 F, CU240E‑2 DP-F, CU240E‑2 PN-F), the fail-safe SINAMICS G120 converter provides five safety functions which are certified according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3:
- Safe Torque Off (STO)
to protect against active movement of the drive - Safe Stop 1 (SS1)
for continuous monitoring of a safe braking ramp - Safely-Limited Speed (SLS)
for protection against dangerous movements when a speed limit is exceeded (the CU240E‑2 DP Failsafe Control Unit has 4 selectable SLS limit values) - Safe Direction (SDI)
This function ensures that the drive can only rotate in the selected direction. - Safe Speed Monitor (SSM)
This function signals if a drive operates below a specific speed/feed velocity (CU240E‑2 DP‑F / CU240E‑2 PN‑F with PROFIsafe).
These functions can be activated by means of PROFIsafe or via the safety inputs.
None of the safety functions require a motor encoder and they are thus much cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.
The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SDI and SSM functions are only permissible for applications where the load can never accelerate when the converter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.