Voltage Rating: 3AC 380-480V, with a tolerance of +10% / -20%
Frequency Range: 47-63 Hz
Rated Power:
Low Overload:
0.55 kW at 150% for 3 seconds
110% for 57 seconds
100% for 240 seconds
High Overload:
0.37 kW at 200% for 3 seconds
150% for 57 seconds
100% for 240 seconds
Integrated Filter: Class A
External Power Supply: 24V
I/O Interface:
6 Digital Inputs (DI)
2 Digital Outputs (DO)
1 Analog Input (AI)
1 Analog Output (AO)
1 Motor Feedback (Mot_t)
Safety Feature: Safe Torque Off (STO)
Integrated Fieldbus: PROFIBUS-DP
Protection Class: IP20 / UL Open Type
Size: FSAA (173 mm x 73 mm x 155 mm) [Height x Width x Depth]
Specifications
SKU / Model
6SL3210-1KE11-8AP2
Weight
1.3 kg
Dimensions
270 × 225 × 85 mm