Complete Drive Module Efficiency (61800-9-2):
| Operating Point Frequency / Current |
Absolute Loss |
Relative Loss |
Efficiency |
|---|---|---|---|
|
0 / 25 %
|
556 W
|
0.5 %
|
92 %
|
|
0 / 50 %
|
754 W
|
0.6 %
|
94.2 %
|
|
0 / 100 %
|
1317 W
|
1.1 %
|
94.8 %
|
|
50 / 25 %
|
611 W
|
0.5 %
|
95.6 %
|
|
50 / 50 %
|
860 W
|
0.7 %
|
96.7 %
|
|
50 / 100 %
|
1547 W
|
1.3 %
|
97 %
|
|
90 / 50 %
|
1013 W
|
0.9 %
|
97.8 %
|
|
90 / 100 %
|
2021 W
|
1.7 %
|
97.8 %
|