[ez-toc]
Overview
Digital fail-safe power module:
F-PM-E PPM 24 V DC/8 A for BU type C0, color code CC52
Other properties:
- Certified up to SIL 3 (IEC 61508), PL e (ISO 13849)
- Approved in accordance with EN 50155, EN 15121, EN 50124, EN 50125 and EN 45545 railway standards for use in rail traffic
- Safety-related shutdown of output modules within the potential group of the F-PM-E
- Two fail-safe digital inputs, for reading of sensor information (1 or 2 channels)
- One fail-safe digital output onboard (ppm switching, up to 2 A, up to SIL 3/PL e)
- Fail-safe digital output and potential supply pp or pm switching can be parameterized
- Parameterizable onboard evaluation of the fail-safe inputs for control of the fail-safe digital outputs and of the potential group
- Digital standard output modules can be shut down up to PL d (ISO 13849) and SIL 2 (IEC 61508) (up to 8 A).
- Can be plugged into type C0 BaseUnits (BU) with automatic coding
- LED display for error, operation, supply voltage and status
- Clear labeling on front of module
- Plain text identification of the module type and function class
- 2D matrix code (order and serial number)
- Connection diagram
- Color coding of the module type DI: white
- Hardware and firmware version
- Color code CC for module-specific color coding of the potentials at the BU terminals
- Complete Article No.
- Optional labeling accessories
- Labeling strips
- Equipment labeling plate
- Optional module-specific color identification of the terminals according to the color code CC
- Optional system-integrated shield connection
- The modules support PROFIsafe in both PROFIBUS and PROFINET configurations.
- They can be used with all fail-safe SIMATIC S7 CPUs
Application
The fail-safe modules of SIPLUS extreme ET 200SP RAIL can be used to implement the safety-related application requirements as an integral part of the overall automation. The safety functions required for fail-safe operation are integrated in these modules. Communication with the fail-safe SIMATIC S7 CPUs is performed by means of PROFIsafe.
The modules can be operated both in centralized and distributed configurations.
Design
Usable BaseUnits
For a single- or multi-conductor connection, BaseUnits with an appropriate number of terminals are available.
A light BaseUnit opens a new load group. The power supply to the sensors must be fed via this BU. The first BU next to the interface module must always be a light BU.
A dark BaseUnit forwards the power supply of the adjacent light BaseUnit on the left via self-assembling voltage buses. A new infeed is therefore only required on the next light BaseUnit to the right.
All variants that correspond to the BU type of the I/O module can be used as BaseUnits.
Color identification of the terminals
The potentials at the terminals of the BaseUnit are defined by the I/O module. Optionally, the potentials of the terminals can be identified by module-specific color-coding labels to prevent wiring errors. The color-coded label that matches the respective I/O module is defined by the color code CCxx of the I/O module. This color code is also printed on the front of the module.
In BaseUnits with the 10 internally jumpered AUX terminals, these can also be identified with color coding labels. For the 10 AUX terminals, color-coding labels are available in red, blue, and yellow/green.
System-integrated shielded connection
For the connection of cable shields that is both space-saving as well as optimized in terms of EMC, a shield connection is available that is quick and easy to mount. This consists of one shield connection element that can be plugged onto the BaseUnit and one shield terminal for each module. The low-impedance connection to the functional ground (DIN rail) is achieved without any additional wiring by the user.
6AG2136-6PA00-1BC0
Siemens SIPLUS ET 200SP F-PM-E 24VDC/8A PPM rail based on 6ES7136-6PA00-0BC0 with conformal coating, -30…+60 °C, OT1 with ST1/2 (+70 °C für 10 minutes), fail-safe power module PROFIsafe, 24 V DC safe shutdown of DQ and F-DQ up to PL D/SIL2 or PL E/SIL3 2 safe digital inputs 1 safe digital output PPM
Visit 6AG2136-6PA00-1BC0
For more our products visit turll.com