Siemens 3RV2421-4BA10 Circuit Breaker S0 Transformer Protection 13–20 A, 325 A Original Brand New

$215.19

Siemens 3RV2421-4BA10 is a compact, high-performance SIRIUS size S0 circuit breaker designed specifically for transformer protection. Featuring an adjustable thermal overload release of 13–20 A and a fixed magnetic trip (N-release) of 325 A, it ensures robust safety for electrical systems with screw terminal connectivity.

Availability: In stock

- +
Global Express Shipping DHL / FedEx / UPS
100% Original & Brand New Factory Sealed Box with 1-Year Warranty
Secure Payment SSL ENCRYPTED
We accept Visa, Mastercard, PayPal, Google Pay and Apple Pay

Overview

The Siemens 3RV2421-4BA10 is part of the renowned SIRIUS modular system, engineered to provide short-circuit and overload protection for transformers. Its “Size S0” footprint makes it an ideal choice for space-constrained control cabinets while maintaining a standard switching capacity. This circuit breaker is optimized for handling the high inrush currents typical of transformer start-ups without nuisance tripping.

Key Function

  • Provides transformer protection with precise A- and N-release ratings

  • Rated A-release 13–20 A and N-release 325 A for optimal current control

  • Screw terminal connections for secure and easy installation

  • Standard switching capacity suitable for a wide range of electrical systems

Benefit

  • Precision Protection: Tailored A-release range (13–20 A) allows for fine-tuned protection based on specific transformer requirements.

  • High Inrush Handling: The 325 A N-release is specifically calibrated for transformer-fed circuits.

  • Space Efficient: The S0 frame size maximizes cabinet density without sacrificing performance.

  • Easy Integration: Part of the Siemens SIRIUS family, ensuring seamless compatibility with contactors and overload relays.

  • Durable Design: Built for industrial environments with high-quality screw terminals for secure wiring.

Technical Specification

  • Product Number: 3RV2421-4BA10

  • Size: S0

  • A-release: 13–20 A

  • N-release: 325 A

  • Connection Type: Screw terminal

  • Switching Capacity: Standard

  • Manufacturer: Siemens

Visit 3RV2421-4BA10 for more detail info

For more our products visit turll

Download

Datasheet in PDF

Weight 0.360 kg
Dimensions 49.00 × 102.00 × 102.00 mm
Brand

SIEMENS

product brand name

SIRIUS

product designation

Circuit breaker

design of the product

For transformer protection

product type designation

3RV2

size of the circuit-breaker

S0

size of contactor can be combined company-specific

S00, S0

product extension auxiliary switch

Yes

power loss [W] for rated value of the current

● at AC in hot operating state

10.5 W

● at AC in hot operating state per pole

3.5 W

insulation voltage with degree of pollution 3 at AC rated value

690 V

surge voltage resistance rated value

6 kV

maximum permissible voltage for safe isolation in networks with grounded star point

● between main and auxiliary circuit

400 V

shock resistance acc. to IEC 60068-2-27

25g / 11 ms

mechanical service life (switching cycles)

● of the main contacts typical

100 000

● of auxiliary contacts typical

100 000

electrical endurance (switching cycles) typical

100 000

reference code acc. to IEC 81346-2

Q

installation altitude at height above sea level maximum

2 000 m

ambient temperature

● during operation

-20 … +60 °C

● during storage

-50 … +80 °C

● during transport

-50 … +80 °C

temperature compensation

-20 … +60 °C

relative humidity during operation

10 … 95 %

number of poles for main current circuit

3

adjustable current response value current of the current-dependent overload release

13 … 20 A

operating voltage

● rated value

20 … 690 V

● at AC-3 rated value maximum

690 V

operating frequency rated value

50 … 60 Hz

operational current rated value

20 A

operational current at AC-3 at 400 V rated value

20 A

operating power at AC-3

● at 230 V rated value

5.5 kW

operating frequency at AC-3 maximum

15 1/h

number of NC contacts for auxiliary contacts

0

number of NO contacts for auxiliary contacts

0

number of CO contacts for auxiliary contacts

0

product function

● ground fault detection

No

● phase failure detection

Yes

trip class

CLASS 10

design of the overload release

thermal

breaking capacity operating short-circuit current (Ics) at AC

● at 240 V rated value

100 kA

● at 400 V rated value

25 kA

● at 500 V rated value

5 kA

● at 690 V rated value

2 kA

breaking capacity maximum short-circuit current (Icu)

● at AC at 240 V rated value

100 kA

● at AC at 400 V rated value

55 kA

● at AC at 500 V rated value

10 kA

● at AC at 690 V rated value

4 kA

response value current of instantaneous short-circuit trip unit

325 A

full-load current (FLA) for 3-phase AC motor

● at 480 V rated value

20 A

● at 600 V rated value

20 A

yielded mechanical performance [hp]

● for single-phase AC motor

— at 110/120 V rated value

1.5 hp

— at 230 V rated value

3 hp

● for 3-phase AC motor

— at 200/208 V rated value

7.5 hp

— at 220/230 V rated value

5 hp

— at 460/480 V rated value

10 hp

product function short circuit protection

Yes

design of the short-circuit trip

magnetic

● at 400 V

gL/gG 63 A

● at 500 V

gL/gG 50 A

● at 690 V

gL/gG 50 A

mounting position

any

fastening method

screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715

required spacing

● for grounded parts at 400 V

● for live parts at 400 V

● for grounded parts at 500 V

● for live parts at 500 V

● for grounded parts at 690 V

● for live parts at 690 V

— downwards

50 mm

— upwards

50 mm

— backwards

0 mm

— at the side

30 mm

— forwards

0 mm

product component removable terminal for auxiliary and control circuit

No

type of electrical connection

● for main current circuit

screw-type terminals

arrangement of electrical connectors for main current circuit

Top and bottom

type of connectable conductor cross-sections

— solid or stranded

2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²)

— finely stranded with core end processing

2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm²

● at AWG cables for main contacts

2x (16 … 12), 2x (14 … 8)

tightening torque

● for main contacts with screw-type terminals

2 … 2.5 N·m

design of screwdriver shaft

Diameter 5 to 6 mm

size of the screwdriver tip

Pozidriv 2

design of the thread of the connection screw

● for main contacts

M4

B10 value

proportion of dangerous failures

● with high demand rate acc. to SN 31920

50 %

failure rate [FIT]

● with low demand rate acc. to SN 31920

50 FIT

T1 value for proof test interval or service life acc. to IEC 61508

10 y

protection class IP on the front acc. to IEC 60529

IP20

touch protection on the front acc. to IEC 60529

finger-safe, for vertical contact from the front

display version for switching status

Handle

other

Railway

last modified:

11/30/2021

Reviews

There are no reviews yet.

Be the first to review “Siemens 3RV2421-4BA10 Circuit Breaker S0 Transformer Protection 13–20 A, 325 A Original Brand New”
Shopping Cart
Siemens 3RV2421-4BA10 Circuit Breaker S0 Transformer Protection 13–20 A, 325 ASiemens 3RV2421-4BA10 Circuit Breaker S0 Transformer Protection 13–20 A, 325 A Original Brand New
$215.19

Availability: In stock

- +
Scroll to Top