★★★★★ Excellent  4.9/5 (1000)
100% Original
🛡️ 1 Year Warranty

Siemens 3VA5112-4ED31-0AA0 Circuit Breaker 3VA5 UL Frame 125, 3-Pole, 125A Original Brand New

$948.70

High-performance 3VA5 UL Frame 125 molded case circuit breaker designed for reliable line protection. Featuring a 125A thermal-magnetic trip unit (TM210), this 3-pole breaker offers a 25 kA breaking capacity at 480V, ensuring safety and durability in industrial electrical systems.

Availability: In stock

- +
Global Express Shipping DHL / FedEx / UPS
100% Original & Brand New Factory Sealed Box with 1-Year Warranty
Secure Payment SSL ENCRYPTED
We accept Visa, Mastercard, PayPal, Google Pay and Apple Pay

Overview

The Siemens 3VA5112-4ED31-0AA0 is a high-performance 3VA5 UL molded case circuit breaker designed for reliable line protection in industrial and commercial electrical systems. Built with UL Frame 125 and Class S breaking capacity, this circuit breaker ensures dependable protection against overloads and short circuits at operating voltages up to 480 V.

Equipped with a TM210 trip unit, permanently set thermal and magnetic protection, and a 25 kA breaking capacity, this breaker delivers consistent performance without the need for additional connections or adjustments.

Benefit

  • Reliable protection for industrial and commercial power distribution

  • High short-circuit breaking capacity for enhanced system safety

  • Maintenance-free settings reduce installation and setup time

  • UL-certified design ensures compliance with North American standards

  • Compact and robust construction for long service life

Function

  • Overload Protection: Permanently set thermal protection (Ir = 125 A)

  • Short-Circuit Protection: Fixed magnetic release (Ii = 10 × In)

  • Line Protection: Ensures safe operation of connected electrical circuits

  • Switching & Protection: Designed for dependable interruption of fault currents

Technical Specification

  • Manufacturer: Siemens

  • Product Number: 3VA5112-4ED31-0AA0

  • Series: 3VA5

  • Frame Size: UL Frame 125

  • Rated Current (In): 125 A

  • Poles: 3-Pole

  • Breaking Capacity: 25 kA @ 480 V

  • Protection Type: TM210, FTFM

  • Overload Setting (Ir): 125 A (fixed)

  • Short-Circuit Setting (Ii): 10 × In (fixed)

  • Connection: Without connection

Visit 3VA5112-4ED31-0AA0 for more detail info

For more our products visit turll

Download

Datasheet in PDF

Weight 0.968 kg
Dimensions 35125254803-210.125125 × -10 mm
Brand

SIEMENS

product brand name

SENTRON

product designation

Molded-case circuit breaker

product designation / according to UL file

SEAS

Product version

System protection

design of the load switch / acc. to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type)

Yes

design of the load switch / acc. to UL 489 / High-Intensity-Discharge circuit breaker (HID Type)

No

design of the load switch / acc. to UL 489 / Switching Duty circuit breaker (SWD Type)

No

design of the overcurrent release

TM210

protection function of the overcurrent release

LI

number of poles

3

rated insulation voltage Ui

800 V

Max. rated operational voltage Ue with DC

500 V

power loss [W] / maximum

30.1 W

Active power loss / for rated value of the current / at AC / in hot operating state / per pole

10.03 W

mechanical service life (switching cycles) / typical

20 000

Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz

8 000

Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz

4 000

electrical endurance (switching cycles) / at 480 V

8 000

electrical endurance (switching cycles) / at 600 V

4 000

Neutral conductors / upgradeable/retrofittable

No

product function

● communication function

No

● other measurement function

No

marking / acc. to UL 489 / 100%-rated breaker

No

operational current

● at 40 °C

125 A

● at 45 °C

122 A

● at 50 °C

119 A

● at 55 °C

117 A

● at 60 °C

114 A

● at 65 °C

112 A

● at 70 °C

109 A

switching capacity class of the circuit breaker

S

breaking capacity maximum short-circuit current (Icu)

breaking capacity operating short-circuit current (Ics)

short-circuit current making capacity (Icm)

● at 415 V

75.6 kA

● at 690 V

7.5 kA

design of short-circuit protection

For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter

breaking capacity current

● at 240 V

65 kA

● at 480 V

25 kA

● at 600 Y/347 V

14 kA

Adjustable response value current / lg min.

125 A

Ground fault protection / tripping switchable / I2t=ON/OFF

No

height [in]

5.51 in

Height

140 mm

width [in]

3 in

Width

76.2 mm

depth [in]

3.01 in

arrangement of electrical connectors / for main current circuit

Without connection

type of electrical connection / for main current circuit

Without

product component

● undervoltage release

No

● voltage trigger

No

● trip indicator

No

number of CO contacts / for auxiliary contacts

0

product extension / optional / motor drive

Yes

protection class IP / on the front

IP40

ambient temperature

● during operation / minimum

-25 °C

● during operation / maximum

70 °C

● during storage / minimum

-40 °C

● during storage / maximum

80 °C

reference code / acc. to IEC 81346-2

Q

certificate of suitability / as approval for NAVAL (no combat vessels) / supplement SB

No

last modified:

10/11/2021

Reviews

There are no reviews yet.

Be the first to review “Siemens 3VA5112-4ED31-0AA0 Circuit Breaker 3VA5 UL Frame 125, 3-Pole, 125A Original Brand New”
Shopping Cart
Siemens 3VA5112-4ED31-0AA0 Circuit Breaker 3VA5 UL Frame 125, 3-Pole, 125ASiemens 3VA5112-4ED31-0AA0 Circuit Breaker 3VA5 UL Frame 125, 3-Pole, 125A Original Brand New
$948.70

Availability: In stock

- +
Scroll to Top