6AG1800-4BA00-7AA0 SIEMENS SIPLUS NET TIM 4R-IE Original Brand New

$11,899.88

6AG1800-4BA00-7AA0

Siemens SIPLUS NET TIM 4R-IE based on 6NH7800-4BA00 with conformal coating, -25…+70 °C, communications module for SIMATIC S7-300, S7-400, C7, PC with two RS-232/RS-485 interfaces for SINAUT Communications via classic WANs and two RJ45 interfaces for SINAUT communication via IP-based networks (WAN or LAN)

- +
SKU: 6AG1800-4BA00-7AA0 Category:
Global Express Shipping DHL / FedEx / UPS
100% Original & Brand New Factory Sealed Box with 1-Year Warranty
Secure Payment SSL ENCRYPTED
We accept Visa, Mastercard, PayPal, Google Pay and Apple Pay

[ez-toc]

Overview

  • SINAUT communications module SIPLUS TIM with four interfaces for SIMATIC S7-300 or as a self-contained device for S7-400 for use in a wide area network (WAN)
  • For universal use in a SINAUT station, node station and control center
  • Internet communication via integrated MSC-VPN tunnel with direct connection to DSL router or operation via IPsec VPN with additional SIMATIC NET components
  • Wireless communication via GPRS router, GPRS modem, or radio devices
  • Wired communication via Ethernet, DSL, dialup modems or dedicated line modem
  • Complete migration of existing wireless, dedicated line and dial-up technology to IP-based network
  • Message buffer for seamless recording of data and support of redundant communication paths
  • Simple configuration and operation without specialist IT knowledge
Note:

SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were adopted from the respective standard products. SIPLUS extreme-specific information was added.

Benefits

  • Protection of investment by combining existing conventional networks with IP-based networks by means of flexible options for connection of up to four SINAUT networks
  • Low-cost construction of the control center by direct connection as independent device to a DSL router, made possible by the integrated MSC-VPN protocol
  • No additional mobile phone service for fixed IP addresses or contracts for private GPRS networks with bidirectional data traffic are necessary, as the VPN is integrated in the ST7 system. No more expensive and complex VPN configuration by IT specialists.
  • High availability of the connections due to possible redundant design of the communication paths
  • Reliable storage of important data. Storage of data message frames (approx. 56,000) including time stamp on TIM in the case of communication path malfunction or power failure
  • Saving of time and money through fast and user-friendly configuration of the connections, as well as through remote programming and diagnostics (PG routing) parallel to the SINAUT data transmission via the WAN or Internet connection
  • Easy maintenance through replacement of modules without PG

Application

  • Use as self-contained central station for the low-cost automation of water/wastewater networks with both complex and simple structures
  • Control and monitoring of energy distribution systems and supply stations, such as oil, gas or district heating networks
  • Preventive maintenance (condition monitoring) of globally distributed systems
  • Monitoring of logistics and traffic control systems
  • Connection of plants with basic or high-level security and availability requirements
  • Use in hybrid networks with dialup, wireless, Ethernet or Internet communication

Design

The TIM 4R-IE offers all the advantages of the SIMATIC S7-300 design:

  • Compact construction;
    double standard width of SIMATIC S7-300 SM modules
  • Two 9-pin D-sub connectors with a combined RS232/RS485 interface for connection to a conventional WAN via an appropriate modem
  • Two RJ45 sockets for connection to Industrial Ethernet or an IP-based network; industrial design with additional retaining collar, for inserting the IE FC RJ45 plug 180
  • 2-pin plug-in terminal strip for connection of the 24 V DC external supply voltage
  • Front LEDs for indicating the module status and the communication
  • Easy to mount;
    the TIM is mounted on an S7-300 DIN rail;
    if integrated into an S7-300 as a CP, it is connected to adjacent modules by means of the bus connector supplied with the TIM. No slot rules apply. As a standalone device, it is linked via one of its Ethernet ports with one or more S7-400 CPUs or with one or more control center PCs.
  • Can be used in the expansion rack (ER) together with the IM 360/361;
  • Can be operated without a fan
  • A backup battery and a memory module (C-PLUG) can be installed as options

Function

The TIM 4R-IE can be used as a stand-alone device, i.e. it is fully functional even without S7-300 CPU. In this stand-alone mode, the TIM is especially suitable as a SINAUT communications processor for the control center PC (e.g. SINAUT ST7cc or ST7sc) or for a SIMATIC S7-400. The TIM is connected to the PC or to the S7-400 via one of the two Ethernet ports of the TIM. If the control center is redundantly designed or if an S7-400 is additionally available there as a higher-level controller, then the TIM performs the SINAUT communication with the stations for all these devices connected to the local Ethernet.

The TIM 4R-IE can also be built into a SIMATIC S7-300 as a CP, e.g. if these devices require redundant transmission paths there or function as node stations at which more than two networks must be merged.

All the devices mentioned can exchange data with other SINAUT ST7 or ST1 partners with the aid of the TIM 4R-IE and specifically via as many as four SINAUT networks that can also be operated in any redundant combination.

The important SINAUT property – saving data complete with a time stamp on the TIM in the event of an interrupted link or failure of the partner – is then available not only for conventional WANs, but also for IP-based networks. Important events, alarms, etc. are not lost and the integrity of information in the control center system archives is assured. Additional security is offered by the optional backup battery of the TIM 4R-IE which prevents the loss of saved data frames if the 24 V supply voltage fails.

For setting up more complex control centers or node stations, several TIM 4R-IE modules can be used. Combinations with TIM 3V-IE Advanced and TIM 3 and other TIM 4 versions are also possible.

As a communications module for the control center PC, the TIM reduces the number of S7 connections that the PC would otherwise have to maintain when directly linked to the stations via an IP-based network to just one (1) connection. In addition, the TIM then separates the local Ethernet from the IP-based network to the stations. Only SINAUT and PG communication with the stations is allowed through. This prevents unnecessary traffic in the WAN which is often not broadband.

A TIM 4R-IE in a redundant control center reduces the data volume in the WAN, and thus reduces the costs for networks with volume-based tariffs, e.g. GPRS. If stations were directly connected to the redundant control center (without a control center TIM 4R-IE), they would send each message frame twice, in order to supply both control center PCs with data. In the case of a control center TIM 4R-IE, the stations only send their message frames once. The doubling of the message frames for supplying both PCs is then performed by the control center TIM 4R-IE.

For data transmission via conventional WANs, the TIM 4R-IE has other, special properties that predetermine its use as a “control center” TIM.

SINAUT ST7 and thus also the TIM 4R-IE are designed for data transmission via the widest range of WANs or combinations of WANs. Mixed networks comprising classical SINAUT WAN networks (dedicated line, wireless, dial-up network) and IP-based networks (fiber optic, DSL, GPRS, Internet etc.) can be configured uniformly using SINAUT, which saves both time and money.

For communication via the Internet, the integrated MSC-VPN tunnel protocol for direct access to DSL routers can be used. The TIM 4R-IE can operate here as an MSC server or MSC client. For communication via GPRS, either the router SCALANCE M874-2 can be connected to the Industrial Ethernet interface (VPN IPsec) or the GSM/GPRS modem MD720-3 (MSC-VPN) to the RS232 interface.

  • The TIM4R-IE has four interfaces for simple and redundant transmission paths:
    • Two combined RS232/RS485 interfaces for connection to standard WANs such as dedicated line, wireless or dial-up network
    • Two RJ45 interfaces for connection to IP-based networks (WAN or LAN) such as fiber-optics, DSL, GPRS, etc.
  • Compact, double-width module that can be used in a wide variety of situations:
    • The TIM handles the SINAUT communication for one or more S7-400 controllers or control center PCs (SINAUT ST7cc or ST7sc) as a stand-alone device (stand-alone without S7-300 CPU); the connection in this case is via Ethernet interfaces of the TIM
    • As a communications processor (CP) in an S7-300
  • The two RJ45 interfaces can be configured either as an MSC-VPN server in the central office or as MSC-VPN client in a station. At the RS232 interface, an MD720-3 can be operated in GPRS mode as MSC-VPN client.
  • The four transmission paths can all be different and operated independently of one another, but also in any redundant combination.
  • Flexible creation of redundant transmission paths via two conventional WANs, via two IP-based networks or a combination of WAN + IP-based network.
  • When installed as a CP in an S7-300, communication is also possible via the backplane bus:
    • With the CPU
    • Via the MPI of this CPU with other CPUs and control center PCs (ST7cc, ST7sc) connected to the MPI bus.
    • With other TIMs in this rack
  • Frame buffer for up to 56 000 data frames
  • Optional backup battery for buffering the stored data frames and the hardware clock if the power fails
  • Up to 62 S7 connections or 128 MSC-VPN tunnel connections (as control center) via IP-based networks and MPI (for S7-300-CPU)
  • The SINAUT TD7 software for the CPU (TD7onCPU) is integrated in the TIM (TD7onTIM); can be used with installation as CP in an S7-300
  • Module replacement possible without PG
    • In stand-alone mode using the optional C-PLUG
    • When installed as a CP in an S7-300 over the memory card of the CPU
  • PG communication is possible parallel to data communication at any time
  • Several TIM 4R-IE can be used per S7-300, also together with one or more TIM 3V-IE Advanced
  • Up to 128 S7 connections via IP-based networks (in MSC tunnel mode)

Controllable communications modules:

  • Control of the GSM/GPRS modems MD720-3 in the GSM or GPRS mode. In GPRS mode, simple 128-bit encryption via the MD720-3 (MSC-VPN tunnel protocol).
  • Operation via SIMATIC NET Ethernet components with high IPsec security standard (e.g. GPRS router or SCALANCE S)
  • Direct operation on a DSL router via MSC tunnel protocol
  • Use of SCALANCE fiber-optic switches for spanning long distances
  • Wireless transmission via IWLAN with SCALANCE W over medium distances
  • Wireless devices from various manufacturers, also for private mobile wireless using the time slot method
  • Modems from different manufacturers, e.g. dedicated line modem

Special properties as “control center” TIM

For data transmission via conventional WANs, the TIM 4R-IE has other, special properties that predetermine its use as a “control center” TIM:

  • In a dialup network the message “Failure of local node” can be switched off. If the control desk PC fails or is temporarily shut down, the control center TIM 4R-IE will not send any failure message to the stations in the dial-up network and therefore saves transmission costs.
  • One especially useful feature during commissioning is the possibility that SINAUT stations can be switched on and off on the control center TIM 4R-IE. This applies not only for stations that are connected via dedicated line/radio, but also for stations in the dial-up network. The last status set for each station is permanently stored on the TIM and is therefore not lost if the power fails or the TIM is restarted.
  • For GPRS, dedicated lines and mobile networks, the message “Node faulty” can be suppressed on the TIM 4R-IE for a programmable period of time. A station failure is then no longer indicated after x unanswered calls (polls), but only when a recognized fault still exists after expiry of the programmed time. This enables the number of failure messages to be reduced in poor-quality networks and it also minimizes the additional message frame traffic that must be processed after each station is restored.

Optional C-PLUG

The most frequent application for the TIM 4R-IE will be its use as a communications module for the control center PC or for an S7-400. The TIM then operates in stand-alone mode, i.e. without S7-300 CPU. The option of saving the TIM configuration data on the MMC card of the CPU, in order to exchange the TIM without a PG in the event of a fault, no longer applies. The saving of configuration data on the C-PLUG, which can be optionally equipped, solves this problem. This means that, even in stand-alone mode, a replacement of the TIM is possible without PG.

6AG1800-4BA00-7AA0

Siemens SIPLUS NET TIM 4R-IE based on 6NH7800-4BA00 with conformal coating, -25…+70 °C, communications module for SIMATIC S7-300, S7-400, C7, PC with two RS-232/RS-485 interfaces for SINAUT Communications via classic WANs and two RJ45 interfaces for SINAUT communication via IP-based networks (WAN or LAN)

Visit 6AG1800-4BA00-7AA0

For more our products visit turll.com

Weight 0.486 kg
Dimensions 130 × 140 × 100 mm

Reviews

There are no reviews yet.

Be the first to review “6AG1800-4BA00-7AA0 SIEMENS SIPLUS NET TIM 4R-IE Original Brand New”
Shopping Cart
6AG1800-4BA00-7AA0 SIEMENS SIPLUS NET TIM 4R-IE6AG1800-4BA00-7AA0 SIEMENS SIPLUS NET TIM 4R-IE Original Brand New
$11,899.88
- +
Scroll to Top