Siemens 3RU2116-1EB0 Overload Relay 2.8–4.0 A Thermal Motor Protection, Class 10, Size S00 Original Brand New

$44.00

A reliable thermal overload relay from the SIRIUS line, designed for motor protection in Size S00 applications. It features an adjustable current setting of 2.8 to 4.0 A, tripping characteristic Class 10, and is suitable for direct contactor mounting. Connections are simple with screw-type terminals for both main and auxiliary circuits.

Availability: In stock

- +
Global Express Shipping DHL / FedEx / UPS
100% Original & Brand New Factory Sealed Box with 1-Year Warranty
Secure Payment SSL ENCRYPTED
We accept Visa, Mastercard, PayPal, Google Pay and Apple Pay

Overview

The Siemens 3RU2116-1EB0 is a high-performance thermal overload relay specifically engineered to protect three-phase motors against excessive heating due to overcurrent, phase failure, or heavy starting. Part of the trusted Siemens SIRIUS industrial control system, this device is crucial for maintaining the operational reliability and longevity of electrical machinery. It is optimally designed for direct mounting onto Size S00 contactors, offering a compact and streamlined installation.

Benefit

  • Reliable Motor Protection: Prevents damage from overloads and excessive temperatures.

  • High Accuracy: Thermal tripping mechanism ensures stable and precise response times.

  • Flexible Reset Options: Includes Manual / Automatic Reset for convenience and safety.

  • Compact & Versatile: Designed for Size S00 applications with easy contactor mounting.

  • Durable Build: Siemens engineering guarantees long-term operational safety and performance.

Key Features

  • Type: Thermal Overload Relay

  • Current Range: 2.8–4.0 A

  • Class: Class 10

  • Mounting: Contactor mounting (Size S00)

  • Main Circuit Connection: Screw terminals

  • Auxiliary Circuit Connection: Screw terminals

  • Reset Mode: Manual or Automatic

Function

The 3RU2116-1EB0 operates on a bimetallic strip principle. When the current flowing through the main circuit terminals exceeds the set value (2.8 A to 4.0 A), the bimetal strips heat up and deform proportionally. If the overcurrent persists for a duration determined by the Class 10 trip curve, the deformation triggers a mechanism that opens the NC auxiliary contact (and closes the NO contact), immediately isolating the motor circuit by de-energizing the main contactor coil. The Manual-Automatic-Reset function determines how the relay is returned to the operational state after a trip.

Visit 3RU2116-1EB0 for more detail info

For more our products visit turll

Download

Datasheet in PDF

Weight 0.160 kg
Dimensions 49.00 × 102.00 × 84.00 mm
Brand

SIEMENS

product brand name

SIRIUS

product designation

thermal overload relay

product type designation

3RU2

size of overload relay

S00

size of contactor can be combined company-specific

S00

power loss [W] for rated value of the current at AC in hot operating state

5.7 W

● per pole

1.9 W

insulation voltage with degree of pollution 3 at AC rated value

690 V

surge voltage resistance rated value

6 kV

maximum permissible voltage for safe isolation in networks with grounded star point

● between auxiliary and auxiliary circuit

440 V

● between main and auxiliary circuit

440 V

shock resistance acc. to IEC 60068-2-27

8g / 11 ms

type of protection according to ATEX directive 2014/34/EU

Ex II (2) GD

certificate of suitability according to ATEX directive 2014/34/EU

DMT 98 ATEX G 001

reference code acc. to IEC 81346-2

F

installation altitude at height above sea level maximum

2 000 m

ambient temperature

● during operation

-40 … +70 °C

● during storage

-55 … +80 °C

● during transport

-55 … +80 °C

temperature compensation

-40 … +60 °C

relative humidity during operation

10 … 95 %

number of poles for main current circuit

3

adjustable current response value current of the current-dependent overload release

2.8 … 4 A

operating voltage

● rated value

690 V

● at AC-3 rated value maximum

690 V

operating frequency rated value

50 … 60 Hz

operational current rated value

4 A

operating power at AC-3

● at 400 V rated value

1.5 kW

● at 500 V rated value

2.2 kW

● at 690 V rated value

3 kW

design of the auxiliary switch

integrated

number of NC contacts for auxiliary contacts

1

number of NO contacts for auxiliary contacts

1

● note

for message "Tripped"

number of CO contacts for auxiliary contacts

0

operational current of auxiliary contacts at AC-15

● at 120 V

3 A

● at 230 V

2 A

● at 400 V

1 A

operational current of auxiliary contacts at DC-13

● at 24 V

2 A

● at 60 V

0.3 A

● at 110 V

0.22 A

● at 125 V

0.22 A

● at 220 V

0.11 A

contact rating of auxiliary contacts according to UL

B600 / R300

trip class

CLASS 10

design of the overload release

thermal

full-load current (FLA) for 3-phase AC motor

● at 480 V rated value

4 A

● at 600 V rated value

4 A

● for short-circuit protection of the auxiliary switch required

fuse gG: 6 A, quick: 10 A

mounting position

any

fastening method

Contactor mounting

product component removable terminal for auxiliary and control circuit

No

type of electrical connection

● for main current circuit

screw-type terminals

● for auxiliary and control circuit

screw-type terminals

arrangement of electrical connectors for main current circuit

Top and bottom

● at AWG cables for main contacts

2x (20 … 16), 2x (18 … 14), 2x 12

type of connectable conductor cross-sections

● for auxiliary contacts

— solid or stranded

2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²)

— finely stranded with core end processing

2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²)

● at AWG cables for auxiliary contacts

2x (20 … 16), 2x (18 … 14)

tightening torque

● for main contacts with screw-type terminals

0.8 … 1.2 N·m

● for auxiliary contacts with screw-type terminals

0.8 … 1.2 N·m

design of screwdriver shaft

Diameter 5 … 6 mm

size of the screwdriver tip

Pozidriv PZ 2

design of the thread of the connection screw

● for main contacts

M3

● of the auxiliary and control contacts

M3

failure rate [FIT] with low demand rate acc. to SN 31920

50 FIT

MTTF with high demand rate

2 280 y

T1 value for proof test interval or service life acc. to IEC 61508

20 y

protection class IP on the front acc. to IEC 60529

IP20

touch protection on the front acc. to IEC 60529

finger-safe, for vertical contact from the front

display version for switching status

Slide switch

Vibration and Shock

last modified:

12/1/2021

Reviews

There are no reviews yet.

Be the first to review “Siemens 3RU2116-1EB0 Overload Relay 2.8–4.0 A Thermal Motor Protection, Class 10, Size S00 Original Brand New”
Shopping Cart
Siemens 3RU2116-1EB0 Overload Relay 2.8–4.0 A Thermal Motor Protection, Class 10, Size S00Siemens 3RU2116-1EB0 Overload Relay 2.8–4.0 A Thermal Motor Protection, Class 10, Size S00 Original Brand New
$44.00

Availability: In stock

- +
Scroll to Top