Special price

SIEMENS

Siemens 6ES7512-1DK01-0AB0 SIMATIC S7-1500, CPU 1512SP-1 PN for ET 200SP Original Brand New

Model / SKU6ES7512-1DK01-0AB0

Siemens CPU 1512SP-1 PN is a compact, powerful controller for the ET 200SP system. It features 200KB program memory, 1MB data memory, and a PROFINET IRT interface. Boasting 48ns bit performance, it is the perfect solution for high-speed automated processes requiring a modular footprint.

Original price was: $1,454.12.Current price is: $883.00.
Available on backorder
  • ConditionOriginal Brand New
  • Warranty12 months

Backorder available · Factory lead time 2–3 weeks.

  • Genuine Products
  • Up to 1-Year Warranty
  • Global Shipping
  • Secure Payment
  • PI / Bank Transfer Available
  • Bulk Quote Support

Description

Overview

The Siemens 6ES7512-1DK01-0AB0 is a high-performance SIMATIC CPU 1512SP-1 PN designed for the ET 200SP distributed I/O system. This Central Processing Unit is engineered for medium-level applications that require high processing speeds and integrated functionality in a compact form factor.

With a lightning-fast 48 ns bit performance, this CPU ensures real-time responsiveness for complex automation tasks. It features a dual-memory structure—200 KB for program logic and 1 MB for data—providing the balance needed for efficient industrial control.

Key Benefit

  • Space-Saving Design: Ideal for control cabinets with limited space, offering the power of an S7-1500 in the ET 200SP form factor.

  • High-Speed Processing: With a command execution time of 48 ns, it handles demanding arithmetic and logic operations with ease.

  • Advanced Connectivity: The integrated PROFINET IRT (Isochronous Real-Time) interface with a 3-port switch allows for flexible network topologies.

  • Scalability: Seamlessly integrates with the wide range of ET 200SP I/O modules.

Function & Features

  • Central Processing Unit for SIMATIC ET 200SP

  • 200 KB work memory for program execution

  • 1 MB work memory for data handling

  • PROFINET IRT interface with integrated 3-port switch

  • Supports deterministic real-time industrial communication

  • Requires SIMATIC Memory Card for operation

  • Requires BusAdapter for ports 1 and 2

Technical Highlight

  • Manufacturer: Siemens

  • Product Number: 6ES7512-1DK01-0AB0

  • CPU Type: SIMATIC DP CPU 1512SP-1 PN

  • Communication: PROFINET IRT

  • Performance: 48 ns per bit

  • Application: Industrial Automation & Control Systems

Download

Datasheet in PDF

Visit 6ES7512-1DK01-0AB0 for more detail info

For more our products visit turll

 

Specifications

SKU / Model6ES7512-1DK01-0AB0
BrandSIEMENS
Product type designationCPU 1512SP-1 PN
HW functional statusFS05
Firmware versionV2.9
● I&M dataYes; I&M0 to I&M3
● Module swapping during operation (hot swapping)Yes; Multi-hot swapping
● Isochronous modeYes; Only with PROFINET; with minimum OB 6x cycle of 625 µs
● STEP 7 TIA Portal configurable/integrated from versionV17 (FW V2.9) / V13 SP1 Update 4 (FW V1.8) or higher
via datasetYes
Mode selector switch1
Type of supply voltageDC
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
● Mains/voltage failure stored energy time5 ms
Current consumption (rated value)0.6 A
Current consumption, max.0.9 A
Inrush current, max.4.7 A; Rated value
I²t0.14 A²·s
Infeed power to the backplane bus8.75 W
Power loss, typ.5.6 W
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
● integrated (for program)200 kbyte
● integrated (for data)1 Mbyte
● Plug-in (SIMATIC Memory Card), max.32 Gbyte
● maintenance-freeYes
for bit operations, typ.48 ns
for word operations, typ.58 ns
for fixed point arithmetic, typ.77 ns
for floating point arithmetic, typ.307 ns
Number of elements (total)4 000; Blocks (OB, FB, FC, DB) and UDTs
● Number range0 ... 65 535
● Number of free cycle OBs100
● Number of time alarm OBs20
● Number of delay alarm OBs20
● Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 500 µs
● Number of process alarm OBs50
● Number of DPV1 alarm OBs3
● Number of isochronous mode OBs1
● Number of technology synchronous alarm OBs2
● Number of startup OBs100
● Number of asynchronous error OBs4
● Number of synchronous error OBs2
● Number of diagnostic alarm OBs1
● per priority class24
— adjustableYes
Retentive data area (incl. timers, counters, flags), max.128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
● Size, max.16 kbyte
● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
● Retentivity adjustableYes
● Retentivity presetNo
● per priority class, max.64 kbyte; max. 16 KB per block
Number of IO modules2 048; max. number of modules / submodules
● Inputs32 kbyte; All inputs are in the process image
● Outputs32 kbyte; All outputs are in the process image
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
● Number of subprocess images, max.32
● Address space per module, max.288 byte; For input and output data respectively
● Address space per station, max.2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules
Number of distributed IO systems32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
● integrated1
● Via CM0
● Modules per rack, max.80; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules
● Quantity of operable ET 200SP modules, max.64
● Quantity of operable ET 200AL modules, max.16
● Number of lines, max.1
● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
● TypeHardware clock
● Backup time6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max.10 s; Typ.: 2 s
● Number16
● supportedYes
● to DP, masterYes; Via CM DP module
● to DP, slaveYes; Via CM DP module
● in AS, masterYes
● in AS, slaveYes
● on Ethernet via NTPYes
Number of PROFINET interfaces1
Number of PROFIBUS interfaces1; Via CM DP module
Optical interfaceYes; via BusAdapter
● RJ 45 (Ethernet)Yes; X1 P3; opt. X1 P1 and X1 P2 via BusAdapter BA 2x RJ45
● integrated switchYes
● BusAdapter (PROFINET)Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC,
● IP protocolYes; IPv4
● PROFINET IO ControllerYes
● PROFINET IO DeviceYes
● Open IE communicationYes; Optionally also encrypted
● Web serverYes
● Media redundancyYes; MRP Automanager according to IEC 62439-2 Edition 2.0
— Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
— Prioritized startupYes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max.128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max.64
— Number of connectable IO Devices for RT, max.128
— of which in line, max.128
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
— for send cycle of 250 µs250 µs to 128 ms
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
— IRTYes
— PROFIenergyYes; per user program
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
— activation/deactivation of I-devicesYes; per user program
— Asset management recordYes; per user program
● RS 485Yes; Via CM DP module
● Number of ports1
● PROFIBUS DP masterYes
● PROFIBUS DP slaveYes
● SIMATIC communicationYes
● Number of DP slaves, max.125; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— PG/OP communicationYes
— EquidistanceNo
— Isochronous modeNo
— Activation/deactivation of DP slavesYes
● 100 MbpsYes
● AutonegotiationYes
● AutocrossingYes
● Industrial Ethernet status LEDYes
● Transmission rate, max.12 Mbit/s
PROFIsafeNo
● Number of connections, max.128; via integrated interfaces of the CPU and connected CPs / CMs
● Number of connections reserved for ES/HMI/web10
● Number of connections via integrated interfaces88
● Number of connections per CP/CM32
● Number of S7 routing paths16
● H-Sync forwardingYes
— Media redundancyYes; only via BusAdapter
— MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
— MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPDYes; Requirement: IRT
— Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max.50
● PG/OP communicationYes; encryption with TLS V1.3 pre-selected
● S7 routingYes
● Data record routingYes
● S7 communication, as serverYes
● S7 communication, as clientYes
● User data per job, max.See online help (S7 communication, user data size)
● TCP/IPYes
— several passive connections per port, supportedYes
● ISO-on-TCP (RFC1006)Yes
● UDPYes
— Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicastYes; Max. 5 multicast circuits
● DHCPYes
● DNSYes
● SNMPYes
● DCPYes
● LLDPYes
● EncryptionYes; Optional
● HTTPYes; Standard and user pages
● HTTPSYes; Standard and user pages
● Runtime license requiredYes; "Small" license required
● OPC UA ClientYes
— Number of connections, max.4
— Number of nodes of the client interfaces, max.1 000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
— Number of simultaneous calls of the client instructions per connection (except OPC_UA_ReadList,OPC_UA_WriteList,OPC_UA_MethodCall), max.1
— Number of simultaneous calls of the client instructions OPC_UA_ReadList,OPC_UA_WriteList and OPC_UA_MethodCall, max.5
— Number of registerable method calls of OPC_UA_MethodCall, max.100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
● OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
— Application authenticationYes
— Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication"anonymous" or by user name & password
— GDS support (certificate management)Yes
— Number of sessions, max.32
— Number of accessible variables, max.50 000
— Number of registerable nodes, max.10 000
— Number of subscriptions per session, max.20
— Sampling interval, min.100 ms
— Publishing interval, min.500 ms
— Number of server methods, max.20
— Number of inputs/outputs per server method, max.20
— Number of monitored items, max.1 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
— Number of nodes for user-defined server interfaces, max.1 000
● Alarms and ConditionsYes
— Number of program alarms100
— Number of alarms for system diagnostics50
● MODBUSYes; MODBUS TCP
Number of login stations for message functions, max.32
Program alarmsYes
Number of configurable program messages, max.5 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.2 500
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 5 engineering systems
Status blockYes; Up to 8 simultaneously (in total across all ES clients)
Single stepNo
Number of breakpoints8
● Status/control variableYes
● VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
— of which status variables, max.200; per job
— of which control variables, max.200; per job
● ForcingYes
● Forcing, variablesPeripheral inputs/outputs
● Number of variables, max.200
● presentYes
● Number of entries, max.1 000
— of which powerfail-proof500
● Number of configurable Traces4; Up to 512 KB of data per trace are possible
● RUN/STOP LEDYes
● ERROR LEDYes
Product ConditionBrand New, New - Backlog, New - No Original Box, New - Original Box Opened, Used - Average, Used - Below Average, Used - Excellent, Used - Fairly Good, Used - Good, Used - Poor, Used - Very Good
Weight0.386 kg
Dimensions10.00 × 12.20 × 6.30 mm

Need bulk pricing or a hard-to-find part?

Request a quote for project quantities, discontinued or obsolete models, and pro-forma invoice / bank transfer orders. Our sourcing team responds fast.

WhatsApp Request a Quote