Special price

SIEMENS

Siemens 3RT2015-1BB42 Power Contactor 7A, 3 kW, 3-Pole, 24V DC, AC-3/AC-3e Original Brand New

Model / SKU3RT2015-1BB42

High-performance SIRIUS power contactor (Size S00) for motor switching up to 3 kW (7 A). It features a low-consumption 24 V DC coil, integrated 1 NC auxiliary contact, and secure screw terminals. Ideal for reliable and efficient industrial control applications.

Original price was: $98.52.Current price is: $36.45.
In stockShips in 1–3 business days
  • ConditionOriginal Brand New
  • Warranty12 months
  • Genuine Products
  • Up to 1-Year Warranty
  • Global Shipping
  • Secure Payment
  • PI / Bank Transfer Available
  • Bulk Quote Support

Description

Overview

The Siemens SIRIUS 3RT2015-1BB42 is a compact, high-performance power contactor designed for switching motors up to 3 kW (400 V). Belonging to the proven SIRIUS line, this size S00 contactor is engineered for industrial reliability and efficiency. It features a 24 V DC operating coil, ensuring low power consumption and reliable switching in modern control systems. The inclusion of an integrated 1 NC (Normally Closed) auxiliary contact and secure screw terminals makes installation straightforward and reduces wiring time.

Key Features & Function

  • Rated current: 7 A (AC-3/AC-3e)

  • Motor control capacity: 3 kW at 400 V

  • Poles: 3-pole configuration for robust performance

  • Coil voltage: 24 V DC for precise control

  • Auxiliary contacts: 1 NC (Normally Closed) for extended functionality

  • Terminal type: Screw terminals for secure wiring

  • Size: S00, compact and space-saving

  • Durability: High-quality Siemens engineering for long-term reliability

Benefit

  • Energy Efficient: The 24 V DC coil offers significantly lower holding power consumption compared to AC coils, reducing operating costs.

  • Space-Saving Design: The compact Size S00 footprint allows for high-density mounting in control cabinets.

  • High Reliability: Rated for AC-3e/AC-3 operation, guaranteeing long electrical and mechanical life under typical industrial load conditions.

  • Simple Integration: Pre-fitted 1 NC auxiliary contact for immediate feedback or interlocking circuit integration.

  • Secure Connection: Robust screw terminals ensure a strong, vibration-resistant connection for all power and control wiring.

Download

Datasheet in PDF

Visit 3RT2015-1BB42 for more detail info

For more our products visit turll

 

Specifications

SKU / Model3RT2015-1BB42
BrandSIEMENS
product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
size of contactorS00
product extension-
● function module for communicationNo
● auxiliary switchYes
power loss [W] for rated value of the current at AC in hot operating state1.2 W
● per pole0.4 W
power loss [W] for rated value of the current without load current share typical4 W
surge voltage resistance-
● of main circuit rated value6 kV
● of auxiliary circuit rated value6 kV
maximum permissible voltage for safe isolation between coil and main contacts acc. to EN 60947-1400 V
shock resistance at rectangular impulse-
shock resistance with sine pulse-
mechanical service life (switching cycles)-
● of contactor typical30 000 000
● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
● of the contactor with added auxiliary switch block typical10 000 000
reference code acc. to IEC 81346-2Q
installation altitude at height above sea level maximum2 000 m
ambient temperature-
● during operation-25 ... +60 °C
● during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C acc. to IEC 60068-2-30 maximum95 %
number of poles for main current circuit3
number of NO contacts for main contacts3
operating voltage at AC-3 rated value maximum690 V
● at AC-1 at 400 V at ambient temperature 40 °C rated value18 A
● at AC-1-
— up to 690 V at ambient temperature 40 °C rated value18 A
— up to 690 V at ambient temperature 60 °C rated value16 A
● at AC-4 at 400 V rated value6.5 A
● at AC-5a up to 690 V rated value15.8 A
● at AC-5b up to 400 V rated value5.8 A
— up to 230 V for current peak value n=20 rated value4 A
— up to 400 V for current peak value n=20 rated value4 A
— up to 500 V for current peak value n=20 rated value3.8 A
— up to 690 V for current peak value n=20 rated value3.6 A
● at AC-6a-
— up to 230 V for current peak value n=30 rated value2.7 A
— up to 400 V for current peak value n=30 rated value2.7 A
— up to 500 V for current peak value n=30 rated value2.5 A
— up to 690 V for current peak value n=30 rated value2.4 A
minimum cross-section in main circuit at maximum AC-1 rated value2.5 mm²
operational current for approx. 200000 operating cycles at AC-4-
operational current-
● at 1 current path at DC-1-
● with 2 current paths in series at DC-1-
● with 3 current paths in series at DC-1-
● at 1 current path at DC-3 at DC-5-
● with 2 current paths in series at DC-3 at DC-5-
● with 3 current paths in series at DC-3 at DC-5-
— at 24 V rated value15 A
— at 110 V rated value15 A
— at 220 V rated value1.2 A
— at 440 V rated value0.14 A
— at 600 V rated value0.14 A
operating power-
● at AC-3-
— at 400 V rated value3 kW
— at 500 V rated value3 kW
— at 690 V rated value4 kW
operating power for approx. 200000 operating cycles at AC-4-
● up to 230 V for current peak value n=20 rated value1.5 kV·A
● up to 400 V for current peak value n=20 rated value2.7 kV·A
● up to 500 V for current peak value n=20 rated value3.3 kV·A
● up to 690 V for current peak value n=20 rated value4.3 kV·A
operating apparent power at AC-6a-
● up to 230 V for current peak value n=30 rated value1 kV·A
● up to 400 V for current peak value n=30 rated value1.8 kV·A
● up to 500 V for current peak value n=30 rated value2.2 kV·A
● up to 690 V for current peak value n=30 rated value2.9 kV·A
short-time withstand current in cold operating state up to 40 °C-
● limited to 1 s switching at zero current maximum120 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximum86 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 10 s switching at zero current maximum67 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximum52 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximum43 A; Use minimum cross-section acc. to AC-1 rated value
no-load switching frequency-
operating frequency-
● at AC-1 maximum1 000 1/h
● at AC-2 maximum750 1/h
● at AC-3 maximum750 1/h
● at AC-4 maximum250 1/h
type of voltage of the control supply voltageDC
control supply voltage at DC-
● rated value24 V
operating range factor control supply voltage rated value of magnet coil at DC-
● initial value0.8
● full-scale value1.1
closing power of magnet coil at DC4 W
holding power of magnet coil at DC4 W
closing delay-
opening delay-
● at DC7 ... 13 ms
arcing time10 ... 15 ms
control version of the switch operating mechanismStandard A1 - A2
number of NC contacts for auxiliary contacts instantaneous contact1
operational current at AC-12 maximum10 A
operational current at AC-15-
● at 230 V rated value10 A
● at 400 V rated value3 A
● at 500 V rated value2 A
● at 690 V rated value1 A
operational current at DC-12-
operational current at DC-13-
● at 24 V rated value10 A
● at 48 V rated value2 A
● at 60 V rated value2 A
● at 110 V rated value1 A
● at 125 V rated value0.9 A
● at 220 V rated value0.3 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
full-load current (FLA) for 3-phase AC motor-
● at 480 V rated value4.8 A
● at 600 V rated value6.1 A
yielded mechanical performance [hp]-
● for single-phase AC motor-
— at 110/120 V rated value0.25 hp
— at 230 V rated value0.75 hp
● for 3-phase AC motor-
— at 200/208 V rated value1.5 hp
— at 220/230 V rated value2 hp
— at 460/480 V rated value3 hp
— at 575/600 V rated value5 hp
contact rating of auxiliary contacts according to ULA600 / Q600
design of the fuse link-
● for short-circuit protection of the main circuit-
— with type of coordination 1 requiredgG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
— with type of assignment 2 requiredgG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
● side-by-side mountingYes
required spacing-
● with side-by-side mounting-
● for grounded parts-
● for live parts-
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
type of electrical connection-
● for main current circuitscrew-type terminals
● for auxiliary and control circuitscrew-type terminals
● at contactor for auxiliary contactsScrew-type terminals
● of magnet coilScrew-type terminals
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
● at AWG cables for main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
connectable conductor cross-section for main contacts-
● solid0.5 ... 4 mm²
● stranded0.5 ... 4 mm²
connectable conductor cross-section for auxiliary contacts-
● solid or stranded0.5 ... 4 mm²
● finely stranded with core end processing0.5 ... 2.5 mm²
type of connectable conductor cross-sections-
— solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
AWG number as coded connectable conductor cross section-
● for main contacts20 ... 12
● for auxiliary contacts20 ... 12
B10 value with high demand rate acc. to SN 319201 000 000
proportion of dangerous failures-
● with low demand rate acc. to SN 3192040 %
● with high demand rate acc. to SN 3192073 %
failure rate [FIT] with low demand rate acc. to SN 31920100 FIT
T1 value for proof test interval or service life acc. to IEC 6150820 y
protection class IP on the front acc. to IEC 60529IP20
touch protection on the front acc. to IEC 60529finger-safe, for vertical contact from the front
suitability for use-
● safety-related switching OFFYes
last modified:11/27/2021
Weight0.292 kg
Dimensions50.00 × 61.50 × 77.50 mm

Need bulk pricing or a hard-to-find part?

Request a quote for project quantities, discontinued or obsolete models, and pro-forma invoice / bank transfer orders. Our sourcing team responds fast.

WhatsApp Request a Quote