Read the frame size from the exact drive
For V20, distinguish direct FSA / FSAC mounting from the FSAA / FSAB arrangement that also requires 6SL3266-1ER00-0VA0. Use the converter data sheet and nameplate to identify the frame. FSA and FSAA are distinct designations; do not shorten or interchange them when matching mounting parts.
Allow for the complete DIN rail installation
Section 3.5 of the V20 instructions distinguishes the converter-frame installation sequences. Check the kit orientation, fastening and space for the power and control conductors. Where a migration arrangement is involved, consult the separate migration-kit section rather than assuming that all mounting plates serve the same purpose.
FSA and FSAC use the documented direct mounting arrangement. For FSAA / FSAB, the illustrated arrangement combines this adapter with migration mounting kit 6SL3266-1ER00-0VA0. Check the two-part arrangement before ordering for those smaller frames.
View product →Include the protective-conductor arrangement
The manual specifies a protective-conductor connection for the DIN rail mounting kit. Use the full installation instructions for earthing and conductor sizing; mechanical attachment to a rail is not a substitute for checking the required electrical connection.