Siemens 5SV3344-4 Residual Current Operated Circuit Breaker, 4-Pole, Type B, 40A, 30mA Original Brand New

$355.30

A high-performance, 4-pole residual current operated circuit breaker (RCCB) designed for superior protection in demanding industrial and commercial environments. Featuring Type B residual current detection for both AC and smooth DC fault currents, a 40 A rated current, and a 30 mA sensitivity.

Availability: In stock

- +
Global Express Shipping DHL / FedEx / UPS
100% Original & Brand New Factory Sealed Box with 1-Year Warranty
Secure Payment SSL ENCRYPTED
We accept Visa, Mastercard, PayPal, Google Pay and Apple Pay

Overview

The Siemens 5SV3344-4 is a high-performance residual current operated circuit breaker (RCCB) engineered to deliver maximum electrical safety in demanding industrial and commercial environments. Featuring 4-pole protection, Type B sensitivity, and short-time-delayed operation, this RCCB ensures reliable protection against AC, pulsating, and smooth DC fault currents. Designed with SIGRES technology, it offers enhanced resistance to harsh ambient conditions, ensuring long-term stability and reduced maintenance needs.

Ideal for advanced applications requiring robust fault-current detection, the Siemens 5SV3344-4 guarantees superior performance even under challenging environmental influences.

Benefits

  • Advanced Protection: Detects AC, pulsating DC, and smooth DC residual currents with Type B sensitivity.

  • Reliable Operation: Short-time-delayed response prevents nuisance tripping and ensures system stability.

  • Harsh-Environment Ready: SIGRES construction improves resistance to moisture, dust, chemical vapors, and temperature fluctuations.

  • Extended Test Interval: Lengthened inspection cycles reduce downtime and maintenance frequency.

  • Versatile Application: Ideal for EV charging stations, industrial systems, drives, converters, and sensitive electronic equipment.

Functions & Features

  • Rated Current (In): 40 A

  • Rated Residual Current: 30 mA

  • Voltage Rating: AC 400 V

  • 4-Pole Configuration

  • Type B Sensitivity – Universal fault-current detection

  • Short-time-delayed tripping for enhanced system reliability

  • SIGRES technology for harsh ambient conditions

  • Extended testing interval for lower operational overhead

  • High endurance design suitable for continuous industrial use

Visit 5SV3344-4 for more detail info

For more our products visit turll

Download

Datasheet in PDF

Weight 0.447 kg
Dimensions 97.00 × 78.00 × 85.00 mm
Brand

SIEMENS

product brand name

SENTRON

product designation

RCCB

design of the product

Short-time delayed

number of poles

4

size of installation devices / acc. to DIN 43880

1

mechanical service life (switching cycles) / typical

10 000

short-circuit current / of series fuse / maximum permissible

100 A

short-circuit current rating

10 kA

switching function / short-term delayed

Yes

overvoltage category

III

supply voltage

● for testing equipment / minimum

195 V

operating frequency

50/60 Hz

supply voltage frequency / rated value

50 Hz

protection class IP

IP20, if the distribution board is installed, with connected conductors

switching capacity current

● acc. to EN 60898 / rated value

0.8 kA

● according to IEC 61008-1 / rated value

0.8 kA

power loss [W]

● for rated value of the current / at AC / in hot operating state / per pole

2.5 W

tripping fault current / rated value

30 mA

operational current

● at 40 °C / rated value

40 A

● at 45 °C / rated value

40 A

● at 50 °C / rated value

40 A

● at 55 °C / rated value

40 A

● at 60 °C / rated value

40 A

● at 65 °C / rated value

40 A

● at 70 °C / rated value

40 A

● at AC / rated value

40 A

residual current type

B

let-through current / permissible

6 200 kA

I2t value / permissible

41 000 A²·s

surge current resistance / rated value

3 kA

product feature / silicon-free

Yes

product extension / installable / supplementary devices

Yes

connectable conductor cross-section / solid

connectable conductor cross-section / stranded

tightening torque / with screw-type terminals

installation depth

70 mm

number of modular width units

4

fastening method

DIN rail (REG)

mounting position

any

ambient temperature / during operation

● minimum

-25 °C

● maximum

45 °C

ambient temperature / during storage

● minimum permissible

-40 °C

● maximum permissible

75 °C

number of test cycles / for environmental testing / acc. to IEC 60068-2-30