Overview

The Siemens 5SV1316-6KK16 RCBO is a high-performance compact residual current circuit breaker with overcurrent protection (RCBO). Designed for residential, commercial, and industrial electrical installations, this device combines protection against short circuits, overloads, and earth leakage currents in a single unit. Its 1-pole+N configuration, rated 16A (B16), and 30 mA Type A residual current sensitivity ensure reliable safety for both people and equipment. With a 6 kA breaking capacity, it is ideal for medium-load circuits up to 1 MW, offering long-term durability and performance.

Benefit

  • Enhanced Safety: Protects against short circuits, overloads, and leakage currents simultaneously.

  • Compact Design: Saves space in distribution boards without compromising performance.

  • Reliable Operation: 6 kA breaking capacity ensures safe disconnection in high-demand scenarios.

  • Type A Sensitivity: Detects both AC and pulsating DC leakage currents, ideal for modern appliances.

  • Easy Installation: 1-pole+N design simplifies wiring and maintenance.

Functions & Features

  • Rated current: B16

  • Residual current sensitivity: 30 mA, Type A

  • Short-circuit capacity: 6 kA

  • Pole configuration: 1-pole + Neutral (N)

  • Compact modular design for DIN rail mounting

  • Conforms to IEC/EN 61009 standards

  • Suitable for residential, commercial, and light industrial circuits

Technical Specification

  • Product Number: 5SV1316-6KK16

  • Rated voltage: 230/400 V AC

  • Rated current: 16 A

  • Tripping characteristics: Type B

  • Residual current: 30 mA, Type A

  • Breaking capacity: 6 kA

  • Mounting: DIN rail

Download

Datasheet in PDF

Visit 5SV1316-6KK16 for more detail info

For more our products visit turll

 

Specifications

SKU / Model5SV1316-6KK16
BrandSIEMENS
product brand nameSENTRON
product designationRCBO
design of the productInstantaneous
number of poles2
number of poles / with protection1
tripping characteristic classB
mechanical service life (switching cycles) / typical10 000
overvoltage categoryIII
degree of pollution2
type of voltage / of the operating voltageAC
insulation voltage (Ui) / rated value253 V
surge voltage resistance / rated value4 000 V
surge current resistance / at (8/20) µs1 kA
supply voltage-
● for testing equipment / minimum195 V
operating frequency50 Hz
supply voltage frequency / rated value50 Hz
protection class IPIP20, if the distribution board is installed, with connected conductors
breaking capacity short-circuit current (Icn) / according to EN 61009-1 / rated value6 kA
switching capacity current-
● acc. to EN 60898 / rated value6 kA
● acc. to IEC 60947-2 / rated value15 kA
rated residual switching capacity (IΔm) / according to IEC 61009-14.5 kA
energy limitation class3
power loss [W]-
● for rated value of the current / at AC / in hot operating state / per pole1.85 W
tripping fault current / rated value30 mA
operational current-
● at 30 °C / rated value16 A
● at 40 °C / rated value15.2 A
● at 45 °C / rated value14.88 A
● at 50 °C / rated value14.4 A
● at 55 °C / rated value14.08 A
● at 60 °C / rated value13.6 A
● at 65 °C / rated value13.28 A
● at 70 °C / rated value12.8 A
● at AC / rated value16 A
residual current typeA
product component / neutral conductor switchingYes
product feature / touch protectionYes
product feature-
● halogen-freeYes
● silicon-freeYes
connectable conductor cross-section / solid-
connectable conductor cross-section / stranded-
connectable conductor cross-section / finely stranded / with core end processing-
tightening torque / with screw-type terminals-
position / of power supply cordEither top or bottom
installation depth70 mm
number of modular width units1
mounting positionany
weight / with packaging133 g
influence of the surrounding temperatureMax. 95% humidity
ambient temperature / during operation-
ambient temperature / during storage-
● minimum-40 °C
● maximum75 °C
number of test cycles / for environmental testing / acc. to IEC 60068-2-3028
reference code-
● acc. to DIN EN 61346-2F
● acc. to IEC 81346-2F
otherDangerous Good
Weight0.132 kg
Dimensions21.00 × 93.00 × 83.00 mm