A compact current-limiting circuit breaker optimized for motor protection. Part of the SIRIUS innovation range, this Size S00 protector features a setting range of 4.5 to 6.3 A and a Class 10 trip characteristic to ensure maximum safety for your electrical motors.

Availability: In stock

- +
Global Express Shipping DHL / FedEx / UPS
100% Original & Brand New Factory Sealed Box with 1-Year Warranty
Secure Payment SSL ENCRYPTED
We accept Visa, Mastercard, PayPal, Google Pay and Apple Pay

Overview

The Siemens 3RV2011-1GA10 is a high-performance circuit breaker designed specifically for the protection of motors. As part of the Siemens SIRIUS 3RV2 series, it provides reliable switching and protection in the event of short circuits or overloads. Its compact Size S00 design allows for high-density installation in control cabinets, while the screw terminal connection ensures a secure and vibration-resistant setup.

Benefit

  • Protects motors from overload and short-circuit damage

  • Class 10 tripping for accurate and fast motor response

  • Compact S00 size saves space in control panels

  • High reliability from Siemens industrial standards

  • Easy installation with screw terminal connections

Function

  • Motor Protection: Tailored to prevent damage to motors during electrical faults.

  • Overload Release: Adjustable bimetal thermal release (4.5…6.3 A) following Class 10 characteristics.

  • Short-Circuit Release: Magnetic instantaneous release fixed at 82 A for rapid fault isolation.

  • Manual Switching: Integrated handle for manual ON/OFF operation and clear status indication.

Technical Specification

  • Brand: Siemens

  • Model Number: 3RV2011-1GA10

  • Current Range: 4.5–6.3 A

  • Magnetic Release: 82 A

  • Trip Class: Class 10

  • Frame Size: S00

  • Connection Type: Screw terminals

  • Protection Type: Overload and short circuit

Visit 3RV2011-1GA10 for more detail info

For more our products visit turll

Download

Datasheet in PDF

Weight 0.348 kg
Dimensions 49.00 × 102.00 × 102.00 mm
Brand

SIEMENS

product brand name

SIRIUS

product designation

Circuit breaker

design of the product

For motor protection

product type designation

3RV2

size of the circuit-breaker

S00

size of contactor can be combined company-specific

S00, S0

product extension auxiliary switch

Yes

power loss [W] for rated value of the current

● at AC in hot operating state

7.25 W

● at AC in hot operating state per pole

2.4 W

insulation voltage with degree of pollution 3 at AC rated value

690 V

surge voltage resistance rated value

6 kV

maximum permissible voltage for safe isolation in networks with grounded star point

● between main and auxiliary circuit

400 V

shock resistance acc. to IEC 60068-2-27

25g / 11 ms

mechanical service life (switching cycles)

● of the main contacts typical

100 000

● of auxiliary contacts typical

100 000

electrical endurance (switching cycles) typical

100 000

type of protection according to ATEX directive 2014/34/EU

Ex II (2) GD

certificate of suitability according to ATEX directive 2014/34/EU

DMT 02 ATEX F 001

reference code acc. to IEC 81346-2

Q

installation altitude at height above sea level maximum

2 000 m

ambient temperature

● during operation

-20 … +60 °C

● during storage

-50 … +80 °C

● during transport

-50 … +80 °C

temperature compensation

-20 … +60 °C

relative humidity during operation

10 … 95 %

number of poles for main current circuit

3

adjustable current response value current of the current-dependent overload release

4.5 … 6.3 A

operating voltage

● rated value

20 … 690 V

● at AC-3 rated value maximum

690 V

operating frequency rated value

50 … 60 Hz

operational current rated value

6.3 A

operational current at AC-3 at 400 V rated value

6.3 A

operating power at AC-3

● at 230 V rated value

1.5 kW

operating frequency at AC-3 maximum

15 1/h

number of NC contacts for auxiliary contacts

0

number of NO contacts for auxiliary contacts

0

number of CO contacts for auxiliary contacts

0

product function

● ground fault detection

No

● phase failure detection

Yes

trip class

CLASS 10

design of the overload release

thermal

breaking capacity operating short-circuit current (Ics) at AC

● at 240 V rated value

100 kA

● at 400 V rated value

100 kA

● at 500 V rated value

100 kA

● at 690 V rated value

4 kA

breaking capacity maximum short-circuit current (Icu)

● at AC at 240 V rated value

100 kA

● at AC at 400 V rated value

100 kA

● at AC at 500 V rated value

100 kA

● at AC at 690 V rated value

6 kA

response value current of instantaneous short-circuit trip unit

82 A

full-load current (FLA) for 3-phase AC motor

● at 480 V rated value

6.3 A

● at 600 V rated value

6.3 A

yielded mechanical performance [hp]

● for single-phase AC motor

— at 110/120 V rated value

0.25 hp

— at 230 V rated value

0.5 hp

● for 3-phase AC motor

— at 200/208 V rated value

1 hp

— at 220/230 V rated value

1.5 hp

— at 460/480 V rated value

3 hp

— at 575/600 V rated value

5 hp

product function short circuit protection

Yes

design of the short-circuit trip

magnetic

● at 400 V

gL/gG 50 A

● at 500 V

gL/gG 40 A

● at 690 V

gL/gG 35 A

mounting position

any

fastening method

screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715

required spacing

● for grounded parts at 400 V

● for live parts at 400 V

● for grounded parts at 500 V

● for live parts at 500 V

● for grounded parts at 690 V

● for live parts at 690 V

— downwards

50 mm

— upwards

50 mm

— backwards

0 mm

— at the side

30 mm

— forwards

0 mm

product component removable terminal for auxiliary and control circuit

No

type of electrical connection

● for main current circuit

screw-type terminals

arrangement of electrical connectors for main current circuit

Top and bottom

type of connectable conductor cross-sections

— solid or stranded

2x (0,75 … 2,5 mm²), 2x 4 mm²

— finely stranded with core end processing

2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²)

● at AWG cables for main contacts

2x (18 … 14), 2x 12

tightening torque

● for main contacts with screw-type terminals

0.8 … 1.2 N·m

design of screwdriver shaft

Diameter 5 to 6 mm

size of the screwdriver tip

Pozidriv 2

design of the thread of the connection screw

● for main contacts

M3

B10 value

proportion of dangerous failures

● with high demand rate acc. to SN 31920

50 %

failure rate [FIT]

● with low demand rate acc. to SN 31920

50 FIT

T1 value for proof test interval or service life acc. to IEC 61508

10 y

protection class IP on the front acc. to IEC 60529

IP20

touch protection on the front acc. to IEC 60529

finger-safe, for vertical contact from the front

display version for switching status

Handle

For use in hazardous locations

Test Certificates Declaration of Conformity

last modified:

10/7/2021

Reviews

There are no reviews yet.

Be the first to review “Siemens 3RV2011-1GA10 Motor Protection Circuit Breaker S00, 4.5–6.3A, Class 10 Original Brand New”
Shopping Cart
Siemens 3RV2011-1GA10 Motor Protection Circuit Breaker S00, 4.5–6.3A, Class 10 Original Brand NewSiemens 3RV2011-1GA10 Motor Protection Circuit Breaker S00, 4.5–6.3A, Class 10 Original Brand New
$59.55

Availability: In stock

- +
Scroll to Top