SIEMENS
Siemens 6ES7214-1HG40-0XB0 SIMATIC S7-1200, CPU 1214C, Compact PLC with 14 DI Original Brand New
High-performance SIMATIC S7-1200 CPU 1214C compact controller. Designed for versatile automation tasks, it features a DC/DC/Relay configuration with 14 digital inputs, 10 relay outputs, and 150 KB of integrated program/data
- ConditionOriginal Brand New
- Warranty12 months
- Genuine Products
- Up to 1-Year Warranty
- Global Shipping
- Secure Payment
- PI / Bank Transfer Available
- Bulk Quote Support
Description
Overview
The Siemens SIMATIC S7-1200 CPU 1214C is a high-performance compact PLC designed for automation applications requiring reliability, flexibility, and efficiency. Equipped with onboard inputs and outputs, including digital and analog channels, this PLC ensures precise control for industrial processes. Ideal for small to medium automation systems, the CPU 1214C supports seamless integration and easy programming with TIA Portal software.
Key Features & Functions
-
Compact Design: Space-saving design for easy installation in control panels.
-
Onboard I/O:
-
14 Digital Inputs (DI), 24 V DC
-
10 Digital Outputs (DO), Relay 2 A
-
2 Analog Inputs (AI), 0-10 V DC
-
-
Power Supply: DC 20.4–28.8 V DC
-
Memory: 150 KB program and data memory
-
Flexible Control: Supports DC/DC/Relay configuration for versatile industrial applications
-
Integration: Fully compatible with SIMATIC TIA Portal for streamlined programming and monitoring
Benefit
-
Efficient automation for small to medium industrial processes
-
Reliable performance with onboard I/O configuration
-
Easy installation and programming for faster deployment
-
Flexible control capabilities with mixed digital and analog channels
-
Compact form factor reduces control panel space requirements
Download
Visit 6ES7214-1HG40-0XB0 for more detail info
For more our products visit turll
Specifications
| SKU / Model | 6ES7214-1HG40-0XB0 |
|---|---|
| Brand | SIEMENS |
| Product type designation | CPU 1214C DC/DC/relay |
| Firmware version | V4.5 |
| ● Programming package | STEP 7 V17 or higher |
| Rated value (DC) | - |
| ● 24 V DC | Yes |
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| ● permissible range, lower limit (DC) | 20.4 V |
| ● permissible range, upper limit (DC) | 28.8 V |
| Current consumption (rated value) | 500 mA; CPU only |
| Current consumption, max. | 1 500 mA; CPU with all expansion modules |
| Inrush current, max. | 12 A; at 28.8 V |
| I²t | 0.8 A²·s |
| for backplane bus (5 V DC), max. | 1 600 mA; Max. 5 V DC for SM and CM |
| ● 24 V | L+ minus 4 V DC min. |
| Power loss, typ. | 12 W |
| ● expandable | No |
| ● integrated | 4 Mbyte |
| ● Plug-in (SIMATIC Memory Card), max. | with SIMATIC memory card |
| ● maintenance-free | Yes |
| ● without battery | Yes |
| for bit operations, typ. | 0.08 µs; / instruction |
| for word operations, typ. | 1.7 µs; / instruction |
| for floating point arithmetic, typ. | 2.3 µs; / instruction |
| Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
| ● Number, max. | Limited only by RAM for code |
| Retentive data area (incl. timers, counters, flags), max. | 14 kbyte |
| ● Size, max. | 8 kbyte; Size of bit memory address area |
| ● per priority class, max. | 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB |
| ● Inputs, adjustable | 1 kbyte |
| ● Outputs, adjustable | 1 kbyte |
| Number of modules per system, max. | 3 comm. modules, 1 signal board, 8 signal modules |
| ● Hardware clock (real-time) | Yes |
| ● Backup time | 480 h; Typical |
| ● Deviation per day, max. | ±60 s/month at 25 °C |
| Number of digital inputs | 14; Integrated |
| ● of which inputs usable for technological functions | 6; HSC (High Speed Counting) |
| Source/sink input | Yes |
| — up to 40 °C, max. | 14 |
| ● Rated value (DC) | 24 V |
| ● for signal "0" | 5 V DC at 1 mA |
| ● for signal "1" | 15 V DC at 2.5 mA |
| — at "0" to "1", min. | 0.2 ms |
| — at "0" to "1", max. | 12.8 ms |
| — parameterizable | Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz |
| Number of digital outputs | 10; Relays |
| ● with resistive load, max. | 2 A |
| ● on lamp load, max. | 30 W with DC, 200 W with AC |
| ● "0" to "1", max. | 10 ms; max. |
| ● "1" to "0", max. | 10 ms; max. |
| ● Number of relay outputs | 10 |
| ● Number of operating cycles, max. | mechanically 10 million, at rated load voltage 100 000 |
| ● unshielded, max. | 150 m |
| Number of analog inputs | 2 |
| ● Voltage | Yes |
| ● 0 to +10 V | Yes |
| — Input resistance (0 to 10 V) | ≥100k ohms |
| ● shielded, max. | 100 m; twisted and shielded |
| Number of analog outputs | 0 |
| ● Resolution with overrange (bit including sign), max. | 10 bit |
| ● Integration time, parameterizable | Yes |
| ● Conversion time (per channel) | 625 µs |
| ● 2-wire sensor | Yes |
| Interface type | PROFINET |
| Isolated | Yes |
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| ● RJ 45 (Ethernet) | Yes |
| ● Number of ports | 1 |
| ● integrated switch | No |
| ● PROFINET IO Controller | Yes |
| ● PROFINET IO Device | Yes |
| ● SIMATIC communication | Yes |
| ● Open IE communication | Yes; Optionally also encrypted |
| ● Web server | Yes |
| ● Media redundancy | No |
| ● Transmission rate, max. | 100 Mbit/s |
| — Prioritized startup | Yes |
| — Number of IO devices with prioritized startup, max. | 16 |
| — Number of connectable IO Devices, max. | 16 |
| — Number of connectable IO Devices for RT, max. | 16 |
| — of which in line, max. | 16 |
| — Activation/deactivation of IO Devices | Yes |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
| — Updating time | The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
| — PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| — Isochronous mode | No |
| — IRT | No |
| — PROFIenergy | Yes |
| — Shared device | Yes |
| — Number of IO Controllers with shared device, max. | 2 |
| Supports protocol for PROFINET IO | Yes |
| PROFIsafe | No |
| PROFIBUS | Yes; CM 1243-5 (master) or CM 1242-5 (slave) required |
| OPC UA | Yes; OPC UA Server |
| AS-Interface | Yes; CM 1243-2 required |
| ● DHCP | No |
| ● SNMP | Yes |
| ● DCP | Yes |
| ● LLDP | Yes |
| — MRP | No |
| — MRPD | No |
| ● S7 routing | Yes |
| ● TCP/IP | Yes |
| ● ISO-on-TCP (RFC1006) | Yes |
| ● UDP | Yes |
| — Data length, max. | 1 472 byte |
| ● User-defined websites | Yes |
| ● Runtime license required | Yes; "Basic" license required |
| ● OPC UA Server | Yes; data access (read, write, subscribe), method call, runtime license required |
| — Application authentication | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
| — User authentication | "anonymous" or by user name & password |
| — Number of sessions, max. | 10 |
| — Number of subscriptions per session, max. | 50 |
| — Sampling interval, min. | 100 ms |
| — Publishing interval, min. | 200 ms |
| — Number of server methods, max. | 20 |
| — Number of monitored items, max. | 1 000 |
| — Number of server interfaces, max. | 2 |
| — Number of nodes for user-defined server interfaces, max. | 2 000 |
| ● MODBUS | Yes |
| ● supported | Yes |
| ● as server | Yes |
| ● as client | Yes |
| ● User data per job, max. | See online help (S7 communication, user data size) |
| ● overall | PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max |
| ● Status/control variable | Yes |
| ● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| ● Forcing | Yes |
| ● present | Yes |
| ● Number of configurable Traces | 2 |
| ● Memory size per trace, max. | 512 kbyte |
| ● RUN/STOP LED | Yes |
| ● ERROR LED | Yes |
| ● MAINT LED | Yes |
| Counter | - |
| ● Number of counters | 6 |
| ● Counting frequency, max. | 100 kHz |
| Frequency measurement | Yes |
| controlled positioning | Yes |
| Number of position-controlled positioning axes, max. | 8 |
| Number of positioning axes via pulse-direction interface | Up to 4 with SB 1222 |
| PID controller | Yes |
| Number of alarm inputs | 4 |
| ● Potential separation digital inputs | 500V AC for 1 minute |
| ● Potential separation digital outputs | Relays |
| ● between the channels | No |
| ● between the channels, in groups of | 2 |
| ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes |
| — Test voltage at air discharge | 8 kV |
| — Test voltage at contact discharge | 6 kV |
| ● Interference immunity on supply lines acc. to IEC 61000-4-4 | Yes |
| ● Interference immunity on signal cables acc. to IEC 61000-4-4 | Yes |
| ● Interference immunity on supply lines acc. to IEC 61000-4-5 | Yes |
| ● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes |
| ● Limit class A, for use in industrial areas | Yes; Group 1 |
| ● Limit class B, for use in residential areas | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
| IP degree of protection | IP20 |
| CE mark | Yes |
| UL approval | Yes |
| cULus | Yes |
| FM approval | Yes |
| RCM (formerly C-TICK) | Yes |
| KC approval | Yes |
| Marine approval | Yes |
| ● Fall height, max. | 0.3 m; five times, in product package |
| ● horizontal installation, min. | -20 °C |
| ● horizontal installation, max. | 60 °C |
| ● vertical installation, min. | -20 °C |
| ● vertical installation, max. | 50 °C |
| ● min. | -40 °C |
| ● max. | 70 °C |
| ● Operation, min. | 795 hPa |
| ● Storage/transport, min. | 660 hPa |
| ● Storage/transport, max. | 1 080 hPa |
| ● Installation altitude, min. | -1 000 m |
| ● Installation altitude, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| ● Operation, max. | 95 %; no condensation |
| ● Vibration resistance during operation acc. to IEC 60068-2-6 | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail |
| ● Operation, tested according to IEC 60068-2-6 | Yes |
| ● tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
| ● SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
| — LAD | Yes |
| — FBD | Yes |
| — SCL | Yes |
| ● User program protection/password protection | Yes |
| ● Copy protection | Yes |
| ● Block protection | Yes |
| ● protection of confidential configuration data | Yes |
| ● Protection level: Write protection | Yes |
| ● Protection level: Read/write protection | Yes |
| ● Protection level: Complete protection | Yes |
| ● adjustable | Yes |
| Width | 110 mm |
| Height | 100 mm |
| Depth | 75 mm |
| Weight, approx. | 435 g |
| last modified: | 4/12/2021 |
| Product Condition | Brand New, New - Backlog, New - No Original Box, New - Original Box Opened, Used - Average, Used - Below Average, Used - Excellent, Used - Fairly Good, Used - Good, Used - Poor, Used - Very Good |
| Weight | 0.452 kg |
| Dimensions | 10.90 × 11.60 × 8.60 mm |
Need bulk pricing or a hard-to-find part?
Request a quote for project quantities, discontinued or obsolete models, and pro-forma invoice / bank transfer orders. Our sourcing team responds fast.