Siemens 3RB3123-4NB0 Electronic Overload Relay 0.32–1.25A for Motor Protection, Size S0 Original Brand New

Model / SKU3RB3123-4NB0

Protect your motors with the Siemens 3RB3123-4NB0. An electronic overload relay for Size S0, featuring a 0.32-1.25A range, adjustable trip classes (5-30), and integrated ground fault detection. Reliable screw-connection technology for industrial automation.

Original price was: $438.34.Current price is: $245.18.
Available on backorder
  • ConditionOriginal Brand New
  • Warranty12 months

Backorder available · Factory lead time 2–3 weeks.

  • Genuine Products
  • Up to 1-Year Warranty
  • Global Shipping
  • Secure Payment
  • PI / Bank Transfer Available
  • Bulk Quote Support

Description

Overview

The Siemens 3RB3123-4NB0 Electronic Overload Relay is a high-performance motor protection device designed to safeguard electric motors from overloads, phase failures, and internal ground faults. Engineered with Siemens’ advanced electronic protection technology, this relay ensures reliable motor operation while minimizing downtime and maintenance costs.

This overload relay supports a current range of 0.32 to 1.25 A, making it ideal for low-current motor applications. It is built in Size S0 and optimized for contactor mounting, allowing seamless integration into motor control systems. The relay features adjustable tripping classes from Class 5 to Class 30, offering flexibility to suit different motor startup conditions and load requirements.

With manual and automatic reset options, screw-type terminals for both main and auxiliary circuits, and internal ground fault detection, the Siemens 3RB3123-4NB0 provides comprehensive protection, accuracy, and long-term reliability in industrial environments.

Key Benefit

1. Advanced Motor Protection

The electronic sensing technology ensures precise current monitoring, protecting motors against overload, phase imbalance, and ground faults more effectively than traditional thermal relays.

2. Adjustable Tripping Class (5–30)

This feature allows users to tailor the relay response to various motor types, including standard-duty and heavy-duty applications.

3. Compact and Space-Saving Design

Size S0 construction enables easy installation in compact control panels without compromising performance.

4. Flexible Reset Options

Supports both manual and automatic reset, providing operational flexibility and improved system uptime.

5. Internal Ground Fault Detection

Integrated ground fault monitoring adds an extra layer of safety, helping to prevent motor damage and electrical hazards.

Function

The Siemens 3RB3123-4NB0 operates by measuring the motor current via integrated current transformers. The electronic evaluation system processes these values and compares them to the set current.

  1. Overload Protection: Triggers if the current exceeds the set threshold for a duration determined by the selected trip class.

  2. Phase Failure Protection: Rapidly detects the loss of a phase to prevent unbalanced heating of the motor windings.

  3. Ground Fault Detection: Monitors for current leakage to earth, providing an extra layer of protection for the motor and cabling.

  4. Reset Modes: Features a flexible Manual/Automatic/Remote Reset selector, allowing for customized recovery protocols after a fault occurs.

Application

The Siemens 3RB3123-4NB0 Overload Relay is suitable for a wide range of industrial and commercial motor protection applications, including:

  • Industrial motor control panels

  • Conveyor systems

  • Pumps and compressors

  • HVAC systems

  • Packaging machinery

  • Automation and control systems

  • Manufacturing and processing plants

This relay is especially recommended for applications where precise protection, reliability, and compact installation are essential.

Technical Highlight

  • Current Range: 0.32 – 1.25 A

  • Relay Type: Electronic overload relay

  • Size: S0

  • Tripping Class: Class 5 to Class 30

  • Mounting Type: Contactor mounting

  • Main Circuit Connection: Screw terminals

  • Auxiliary Circuit Connection: Screw terminals

  • Reset Type: Manual / Automatic

  • Protection Features: Overload, phase failure, internal ground fault detection

Installation and Maintenance

Mounting the 3RB3123-4NB0 is straightforward. It features screw terminals for both the main circuit and the auxiliary circuit. The relay is designed for direct mounting onto S0 contactors, but standalone installation is also possible using separate mounting brackets. Maintenance is minimal; however, periodic testing of the "Test/Stop" function is recommended to ensure the auxiliary contacts are functioning correctly.

Visit 3RB3123-4NB0 for more detail info

For more our products visit turll

Download

Datasheet in PDF

Specifications

SKU / Model3RB3123-4NB0
BrandSIEMENS
product brand nameSIRIUS
product designationsolid-state overload relay
product type designation3RB3
size of overload relayS0
size of contactor can be combined company-specificS0
power loss [W] for rated value of the current at AC in hot operating state0.1 W
● per pole0.03 W
insulation voltage with degree of pollution 3 at AC rated value690 V
surge voltage resistance rated value6 kV
maximum permissible voltage for safe isolation in networks with grounded star point-
● between auxiliary and auxiliary circuit300 V
● between main and auxiliary circuit690 V
shock resistance15g / 11 ms
● acc. to IEC 60068-2-2715g / 11 ms; Signaling contact 97 / 98 in position "Tripped": 9g / 11 ms
vibration resistance1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles
thermal current1.25 A
type of protection according to ATEX directive 2014/34/EUEx II (2) G [Ex e] [Ex d] [Ex px] ; Ex II (2) D [Ex t] [Ex p]
certificate of suitability according to ATEX directive 2014/34/EUPTB 09 ATEX 3001
reference code acc. to IEC 81346-2F
installation altitude at height above sea level maximum2 000 m
ambient temperature-
● during operation-25 ... +60 °C
● during storage-40 ... +80 °C
● during transport-40 ... +80 °C
temperature compensation-25 ... +60 °C
relative humidity during operation10 ... 95 %
number of poles for main current circuit3
adjustable current response value current of the current-dependent overload release0.32 ... 1.25 A
operating voltage-
● rated value690 V
● for remote-reset function at DC24 V
● at AC-3 rated value maximum690 V
operating frequency rated value50 ... 60 Hz
operational current rated value1.25 A
operating power-
● for 3-phase motors at 400 V at 50 Hz0.12 ... 0.37 kW
● for AC motors at 500 V at 50 Hz0.12 ... 0.55 kW
● for AC motors at 690 V at 50 Hz0.18 ... 0.75 kW
design of the auxiliary switchintegrated
number of NC contacts for auxiliary contacts1
number of NO contacts for auxiliary contacts1
● notefor message "tripped"
number of CO contacts for auxiliary contacts0
operational current of auxiliary contacts at AC-15-
● at 120 V4 A
● at 230 V3 A
operational current of auxiliary contacts at DC-13-
● at 24 V2 A
● at 60 V0.55 A
● at 110 V0.3 A
● at 125 V0.3 A
● at 220 V0.11 A
trip classCLASS 5E, 10E, 20E and 30E adjustable
design of the overload releaseelectronic
response value current of the grounding protection minimum0.75 x IMotor
response time of the grounding protection in settled state1 000 ms
operating range of the grounding protection relating to current set value-
● minimumIMotor > lower current setting value
● maximumIMotor < upper current setting value x 3.5
full-load current (FLA) for 3-phase AC motor-
● at 480 V rated value1.25 A
● at 600 V rated value1.25 A
contact rating of auxiliary contacts according to ULB600 / R300
design of the fuse link-
● for short-circuit protection of the main circuit-
— with type of coordination 1 requiredgG: 35 A, RK5: 6 A
— with type of assignment 2 requiredgG: 6 A
● for short-circuit protection of the auxiliary switch requiredfuse gG: 6 A
mounting positionany
fastening methodContactor mounting
product component removable terminal for auxiliary and control circuitYes
type of electrical connection-
● for main current circuitscrew-type terminals
● for auxiliary and control circuitscrew-type terminals
arrangement of electrical connectors for main current circuitTop and bottom
— stranded2x 10 mm²
● at AWG cables for main contacts1x (16 ... 8), 2x (16 ... 8)
type of connectable conductor cross-sections-
● for auxiliary contacts-
— solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
— solid or stranded1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²)
— finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
● at AWG cables for auxiliary contacts1x (20 ... 14), 2x (20 ... 14)
tightening torque-
● for main contacts with screw-type terminals2 ... 2.5 N·m
● for auxiliary contacts with screw-type terminals0.8 ... 1.2 N·m
design of screwdriver shaftDiameter 5 to 6 mm
size of the screwdriver tipPozidriv PZ 2
design of the thread of the connection screw-
● for main contactsM4
● of the auxiliary and control contactsM3
protection class IP on the front acc. to IEC 60529IP20
touch protection on the front acc. to IEC 60529finger-safe, for vertical contact from the front
type of voltage supply via input/output link masterNo
conducted interference-
● due to burst acc. to IEC 61000-4-42 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3
● due to conductor-earth surge acc. to IEC 61000-4-52 kV (line to earth) corresponds to degree of severity 3
● due to conductor-conductor surge acc. to IEC 61000-4-51 kV (line to line) corresponds to degree of severity 3
● due to high-frequency radiation acc. to IEC 61000-4-610 V in frequency range 0.15 to 80 MHz, modulation 80 % AM with 1 kHz
field-based interference acc. to IEC 61000-4-310 V/m
electrostatic discharge acc. to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
display version for switching statusSlide switch
last modified:12/15/2020
Weight0.215 kg
Dimensions98.00 × 116.00 × 57.00 mm