6ES7142-6BR00-0BB0
Siemens SIMATIC ET 200eco PN, DQ 8x 24 V DC/2A, M12-L, 8x M12, single and double assignment, source output (PNP,switching to P potential), substitute value output, channel diagnostics for wire break and short-circuit at the output, shared device with 2 controllers, 0.25 ms isochronous mode, prioritized startup, MSO, MRP, S2 redundancy, I&M0…3, multi-fieldbus, PN IO, Ethernet IP, Modbus TCP, degree of protection IP67 / IP69K
Overview
- Digital I/O devices with 2x M12 L-coded power connectors and 45 mm width
- 8 digital input signals with 8xM12 connection
- 16 digital input signals with 8xM12 connection
- 8 digital output signals 8-channel digital output module 0.5A with 8xM12 connection
- 8 digital output signals 2A with 8xM12 connection
- 16 digital input/output signals 0.5A/2A with 8xM12 connection
- Digital I/O devices with 2x M12 A-coded power connectors and 30 mm width
- 8 digital input signals with 4xM12 connection
- 8 digital output signals 0.5 A with 4xM12 connection
- 8 digital output signals 1.3 A with 4xM12 connection
- Digital I/O devices with 2x M12 A-coded power connectors and 60 mm width
- 8 digital input signals with 8xM12 connection
- 16 digital input signals with 8xM12 connection
- 8 digital output signals 1.3 A with 8xM12 connection
- 8 digital output signals 2 A with 8xM12 connection
- 16 digital output signals 1.3 A with 8xM12 connection
- 8 digital input/output signals 1.3 A with 8xM12 connection
Application
Digital inputs record 24 V DC signals in the plant and forward them to the controller. Switches and 2, 3 or 4-wire proximity switches can be connected.
Digital outputs switch 24 V DC voltages in the plant, thus transferring internal signals from the controller to the plant. Solenoid valves, DC contactors, and indicator lights can be connected.
The 30 mm and 45 mm wide I/O devices are especially suitable for use in extremely confined spaces. All I/O devices have configurable parameters and diagnostic functions and can thus be freely adapted to the respective process requirements.
Function
In addition to the general functions of the ET 200eco PN I/O system, digital distributed I/O devices with M12 L-coded power connectors have other functions:
- Isochronous operation down to the sensor/actuator
- Shared device
- MSI/MSO
- S2 redundancy
- Safety-related switch-off of digital outputs according to IEC 62061 (SILCL2) and ISO 13849-1 (Cat 3/PL d)
- Monitoring of supply voltage 1L+ and load voltage 2L+
- Multi-protocol capability: Operation on Ethernet controllers via the PROFINET, EtherNet/IP and Modbus protocols
Download