ā˜…ā˜…ā˜…ā˜…ā˜… Excellent  4.9/5 (1000)
āœ” 100% Original
šŸ›”ļø 1 Year Warranty

3RT2037-1AL20 Siemens Sirius Power Contactor Original Brand New

$147.15

3RT2037-1AL20 SiemensĀ 

Power contactor, AC-3e/AC-3, 65 A, 30 kW / 400 V, 3-pole, 230 V AC, 50/60 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S2

- +
SKU: 3RT2037-1AL20 Category:
Global Express Shipping DHL / FedEx / UPS
100% Original & Brand New Factory Sealed Box with 1-Year Warranty
Secure Payment SSL ENCRYPTED
We accept Visa, Mastercard, PayPal, Google Pay and Apple Pay

Overview

Our power range of contactors for switching IE2 motors and highly efficient IE3 and IE4 motors:

Standards

IECĀ 60947‑1, IECĀ 60947‑4‑1, IECĀ 60947‑5‑1 (auxiliary switches)

Contactors with increased tamper protection

Increased tamper protection is ensured either by using our contactor versions with factory-installed, permanently mounted auxiliary switches which are protected against mechanical external actuation (e.g. 3RT20..‑…..‑3MA0 or 3RT10..‑…..‑3PA0 contactors), or by using theĀ 3RT2916‑4MA10Ā orĀ 3RT1926‑4MA10 sealable coverĀ as an accessory.

Protection of the device connections against short circuit, overload, and overvoltage

All connections must generally be protected against overload and short circuits using suitable measures. Different constraints must be considered depending on the type of connection:

Short-circuit and overload protection of main connections

For information on the protection of a free-standing contactor,Ā see the technical product data sheet.

For more information on device combinations such as contactor with overload relay or contactor with circuit breaker as motor feeder,Ā refer to

Short-circuit and overload protection of auxiliary connections

For information on the protection of auxiliary contacts,Ā see the technical product data sheet.

Short-circuit and overload protection of control supply voltage or supply voltage connections

First of all, the relevant standards and regulations for configuring control panels and the parts and components installed in them must be taken into account, for example for cable dimensioning.

One possible protection for these circuits could be the selection of a suitable power supply, i.e. one with a current-limiting function. In the selection of the source and the connecting cable, the load characteristics of the contactor must be considered (short-time inrush current peaks for solid-state contactor operating mechanisms, switch-on power, holding power). The same applies to the selection of suitable protection devices.

If there are further switching elements in the circuit, such as the auxiliary contact system of an overload relay that operates the contactor, the short-circuit protection necessary for this must also be considered.

Short-circuit and overload protection of contactors with digital input

According to the PLC input types specified in IECĀ 60947‑4‑1, a typical rated current of 20Ā mA applies to these inputs. The inputs can be protected accordingly.

  • Contactors with PLC and F‑PLC inputs:
    • For 3RT10..‑.P marked with IN+/IN-
    • For 3RT10..‑.S, ‑.N and 3RT20..‑.S marked with +/-
  • Supply voltage connections A1 – A2:
    • For 3RT10..‑.N, ‑.P and 3RT20..‑.S, protection must be provided according to load characteristics.
      For information on power consumption.
    • With 3RT10..‑.S, the protection is already integrated.

Short-circuit and overload protection of other connections

The contactor version 3RT10..‑.P with remaining lifetime indicator (RLT) has additional connections H1 – H2 and R1 – R2.

If A1 – A2 is already protected, further protection of H1 – H2 is not required.

For information on the protection of R1 – R2.

Protection against overvoltage at the control supply voltage connection

3RT20 contactors supplied without a coil circuit can be retrofitted with RC elements, varistors, diodes or diode assemblies (assembly of diode and Zener diode for short break times) for damping opening surges in the coil and must be ordered separately as accessory.

The 3RT10 contactors are already equipped with coil damping (varistor).

Note:

The break times of the contactor, the opening delay times of the NO contacts and the closing delay times of the NC contacts increase with damping.

Connection methods

Main circuit

  • 3RT201 and 3RT202 contactors:
    Screw terminals or spring-loaded terminals;
    spring-loaded terminals with convenient plug-in design for device connectors
  • 3RT203 and 3RT204 contactors:
    Screw terminals with box terminal;
    direct connection to the connecting bar possible with cable lugs for 3RT204 when the box terminal is removed.
  • 3RT10 contactors:
    Screw terminals with connecting bars that the cables can be connected to using either cable lugs or flexible or rigid busbars. Alternatively, box terminals are available as accessories.

Auxiliary and control circuit

The 3RT contactors are available with screw terminals or spring-loaded terminals.

Electromagnetic compatibility

The contactors fulfill the requirements for environment category A.

Note:

When the contactors are usedĀ in an environment with frequency converters, the configuration notes must be observed.

Contact reliability of auxiliary contacts

If voltages ≤ 110Ā V and currents ≤ 100Ā mA are to be switched, the auxiliary contacts of the 3RT contactors or 3RH contactor relays should be used as they guarantee a high level of contact reliability.

These auxiliary contacts are especially suitable for solid-state circuits with currents ≄ 1Ā mA at a voltage of 17Ā V and higher.

Motor protection

3RT20 contactors

For protection against overload,Ā 3RU2 thermal overload relaysĀ orĀ 3RB3 electronic overload relaysĀ can be mounted on the 3RT20 contactors.

3RT10 contactors

For protection against overload,Ā 3RB2 electronic overload relaysĀ can be mounted on the 3RT10 contactors.

Plant and application monitoring

For monitoring and measuring in the application, theĀ 3RR2 monitoring relaysĀ can be mounted on the 3RT20 contactors.

Contactors with voltage tap-off

The 3RT20 contactors with voltage tap-off are special versions for mounting theĀ SIRIUS 3RA27 function modulesĀ for connection to the control system via IO‑Link or AS‑Interface.

Without a function module, these contactors can be used like the standard versions.

Operating mechanism types

3RT20 contactors

The standard versions are available with AC or DC operating mechanisms or as contactor versions with a wide-range solid-state operating mechanism and a universal actuating voltage (AC or DC operation possible).

Versions with solid-state operating mechanisms for AC or DC operation with a fail-safe PLC input are also available for the 3RT203 and 3RT204 contactors.

Control takes place via the control supply voltage connection A1Ā –Ā A2 with varying operating ranges (see the technical product data sheetĀ for further details).

DC coupling contactors with reduced power consumption are also ideally suited for connection to the controller.

3RT10 contactors

The operating mechanisms are powered via a supply voltage with an operating range from 0.8Ā toĀ 1.1Ā xĀ Us, optionally also controlled depending on the chosen mode of operation. Various rated voltage ranges are available for AC/DC control.

The following control and/or operating mechanism versions can be selected for contactors 3RT105 to 3RT107:

  • 3RT10..-.A contactors:
    Standard operating mechanism for AC and DC operation (reduced closing and holding power)
  • Solid-state operating mechanisms:
    Overvoltage damping of the operating mechanism coil is already integrated in the electronics for contactors with solid-state operating mechanisms.
    The following versions are available:

    • 3RT10..‑.N contactors:
      With two operating modes: Direct control or via PLC input (24Ā V DC)
    • 3RT10..-.P contactors:
      Control via PLC input (24Ā V DC) only, but with additional remaining lifetime indicator (RLT)
    • 3RT10..-.S contactors:
      Control via fail-safe PLC input (24Ā V DC) only, for simplification of safety applications (without operating mode selection)
Replacing solenoid coils, operating mechanisms, or spare contacts

3RT20 contactors

Coil replacement is possible for contactors 3RT202 to 3RT204.

NOTICE:
Removal or changing of the operating mechanism or spare contacts is not permitted for 3RT20..‑.S contactors with fail-safe control.

3RT10 contactors

The operating mechanisms for 3RT10..‑.A/‑.N/‑.P contactors are removable and can be replaced simply by unlocking and pulling them out.

NOTICE:
Removal or changing of the operating mechanism is not permitted for 3RT10..‑.S contactors with fail-safe control.

Fitting auxiliary contacts and mounting additional auxiliary switches

Equipment as supplied

  • 3RT20 contactors:
    • 3RT201 contactor:
      An auxiliary contact is integrated in the basic unit.
    • 3RT202 to 3RT204 contactors:
      The basic units contain two integrated auxiliary contacts (1 NOĀ +Ā 1Ā NC).
  • 3RT10 contactors:
    These contactors are supplied with two laterally mounted auxiliary switches. The fitting of auxiliary switches is possible on the front and on the side.

Expansion possibilities

All basic units (with the exception of coupling contactors in sizes S00 and S0) can be expanded using auxiliary switches. The permitted configuration must be taken into account.

Connection of contactors to fail-safe control modules

While contactors with smaller power ratings can be connected directly to the outputs of fail-safe controllers, implementing safety-related applications with standard contactors with higher power is much more complicated and elaborate because of the necessary coupling links.

Due to their fail-safe control input, special contactors provide a much simpler way of doing this:

  • 3RT20..‑.S contactors in sizes S2 and S3
  • 3RT10..‑.S contactors in sizes S6 to S12

3RT2037-1AL20 Siemens

Siemens power contactor, AC-3e/AC-3, 65 A, 30 kW / 400 V, 3-pole, 230 V AC, 50/60 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S2

Weight 1.049 kg
Dimensions 62 × 122.5 × 142 mm

Reviews

There are no reviews yet.

Be the first to review “3RT2037-1AL20 Siemens Sirius Power Contactor Original Brand New”