Siemens 3RV2011-0HA10 Motor Protection Circuit Breaker S00, 0.55–0.8A, Class 10 Original Brand New
A compact current-limiting circuit breaker designed for motor protection up to size S00. Featuring a CLASS 10 thermal overload release (0.55…0.8 A) and a magnetic short-circuit release of 10 A, it ensures reliable switching and protection in industrial environments.
- ConditionOriginal Brand New
- Warranty12 months
- Genuine Products
- Up to 1-Year Warranty
- Global Shipping
- Secure Payment
- PI / Bank Transfer Available
- Bulk Quote Support
Description
Overview
The Siemens 3RV2011-0HA10 is a high-quality motor protection circuit breaker from the trusted Siemens 3RV2 series. Designed in size S00, this device provides reliable protection for motors against overloads and short circuits. Featuring a Class 10 A-release, adjustable current range of 0.55 to 0.8 A, and screw terminals, it ensures safe, efficient, and long-lasting motor operation in industrial and commercial environments.
Benefit
-
Space-Saving Design: The S00 size allows for high-density mounting in control cabinets.
-
Reliable Protection: Integrated bimetallic heaters provide CLASS 10 overload protection.
-
Global Compliance: Tested and certified for worldwide use (IEC, UL, CSA).
-
Ease of Connection: Standard screw terminals ensure secure and fast wiring.
Function
-
Short-Circuit Protection: Instantaneous N-release at 10 A to prevent system damage.
-
Overload Protection: Adjustable thermal release range from 0.55 to 0.8 A.
-
Phase Failure Sensitivity: Enhanced safety in the event of a lost phase.
-
Manual Switching: Integrated handle for manual ON/OFF operation and trip signaling.
Technical Specification
-
Manufacturer: Siemens
-
Product Number: 3RV2011-0HA10
-
Breaker Size: S00
-
Current Range (A-release): 0.55 – 0.8 A
-
Trip Class: Class 10
-
N-release: 10 A
-
Connection Type: Screw terminal
-
Switching Capacity: Standard
-
Application: Motor protection
Download
Visit 3RV2011-0HA10 for more detail info
For more our products visit turll
Specifications
| SKU / Model | 3RV2011-0HA10 |
|---|---|
| Brand | SIEMENS |
| product brand name | SIRIUS |
| product designation | Circuit breaker |
| design of the product | For motor protection |
| product type designation | 3RV2 |
| size of the circuit-breaker | S00 |
| size of contactor can be combined company-specific | S00, S0 |
| product extension auxiliary switch | Yes |
| power loss [W] for rated value of the current | - |
| ● at AC in hot operating state | 7.25 W |
| ● at AC in hot operating state per pole | 2.4 W |
| insulation voltage with degree of pollution 3 at AC rated value | 690 V |
| surge voltage resistance rated value | 6 kV |
| maximum permissible voltage for safe isolation in networks with grounded star point | - |
| ● between main and auxiliary circuit | 400 V |
| shock resistance acc. to IEC 60068-2-27 | 25g / 11 ms |
| mechanical service life (switching cycles) | - |
| ● of the main contacts typical | 100 000 |
| ● of auxiliary contacts typical | 100 000 |
| electrical endurance (switching cycles) typical | 100 000 |
| type of protection according to ATEX directive 2014/34/EU | Ex II (2) GD |
| certificate of suitability according to ATEX directive 2014/34/EU | DMT 02 ATEX F 001 |
| reference code acc. to IEC 81346-2 | Q |
| installation altitude at height above sea level maximum | 2 000 m |
| ambient temperature | - |
| ● during operation | -20 ... +60 °C |
| ● during storage | -50 ... +80 °C |
| ● during transport | -50 ... +80 °C |
| temperature compensation | -20 ... +60 °C |
| relative humidity during operation | 10 ... 95 % |
| number of poles for main current circuit | 3 |
| adjustable current response value current of the current-dependent overload release | 0.55 ... 0.8 A |
| operating voltage | - |
| ● rated value | 20 ... 690 V |
| ● at AC-3 rated value maximum | 690 V |
| operating frequency rated value | 50 ... 60 Hz |
| operational current rated value | 0.8 A |
| operational current at AC-3 at 400 V rated value | 0.8 A |
| operating power at AC-3 | - |
| ● at 230 V rated value | 0.1 kW |
| operating frequency at AC-3 maximum | 15 1/h |
| number of NC contacts for auxiliary contacts | 0 |
| number of NO contacts for auxiliary contacts | 0 |
| number of CO contacts for auxiliary contacts | 0 |
| product function | - |
| ● ground fault detection | No |
| ● phase failure detection | Yes |
| trip class | CLASS 10 |
| design of the overload release | thermal |
| breaking capacity operating short-circuit current (Ics) at AC | - |
| ● at 240 V rated value | 100 kA |
| ● at 400 V rated value | 100 kA |
| ● at 500 V rated value | 100 kA |
| ● at 690 V rated value | 100 kA |
| breaking capacity maximum short-circuit current (Icu) | - |
| ● at AC at 240 V rated value | 100 kA |
| ● at AC at 400 V rated value | 100 kA |
| ● at AC at 500 V rated value | 100 kA |
| ● at AC at 690 V rated value | 100 kA |
| response value current of instantaneous short-circuit trip unit | 10 A |
| full-load current (FLA) for 3-phase AC motor | - |
| ● at 480 V rated value | 0.8 A |
| ● at 600 V rated value | 0.8 A |
| product function short circuit protection | Yes |
| design of the short-circuit trip | magnetic |
| design of the fuse link for IT network for short-circuit protection of the main circuit | - |
| ● at 690 V | gL/gG 6 A |
| mounting position | any |
| fastening method | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 |
| required spacing | - |
| ● for grounded parts at 400 V | - |
| ● for live parts at 400 V | - |
| ● for grounded parts at 500 V | - |
| ● for live parts at 500 V | - |
| ● for grounded parts at 690 V | - |
| ● for live parts at 690 V | - |
| — downwards | 50 mm |
| — upwards | 50 mm |
| — backwards | 0 mm |
| — at the side | 30 mm |
| — forwards | 0 mm |
| product component removable terminal for auxiliary and control circuit | No |
| type of electrical connection | - |
| ● for main current circuit | screw-type terminals |
| arrangement of electrical connectors for main current circuit | Top and bottom |
| type of connectable conductor cross-sections | - |
| — solid or stranded | 2x (0,75 ... 2,5 mm²), 2x 4 mm² |
| — finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| ● at AWG cables for main contacts | 2x (18 ... 14), 2x 12 |
| tightening torque | - |
| ● for main contacts with screw-type terminals | 0.8 ... 1.2 N·m |
| design of screwdriver shaft | Diameter 5 to 6 mm |
| size of the screwdriver tip | Pozidriv 2 |
| design of the thread of the connection screw | - |
| ● for main contacts | M3 |
| B10 value | - |
| proportion of dangerous failures | - |
| ● with high demand rate acc. to SN 31920 | 50 % |
| failure rate [FIT] | - |
| ● with low demand rate acc. to SN 31920 | 50 FIT |
| T1 value for proof test interval or service life acc. to IEC 61508 | 10 y |
| protection class IP on the front acc. to IEC 60529 | IP20 |
| touch protection on the front acc. to IEC 60529 | finger-safe, for vertical contact from the front |
| display version for switching status | Handle |
| other | Railway |
| last modified: | 11/16/2021 |
| Weight | 0.275 kg |
| Dimensions | 49.00 × 102.00 × 102.00 mm |