6ES7315-7TJ10-0AB0
Siemens SIMATIC S7-300, CPU 315T-3 PN/DP, Central processing unit for PLC and technology tasks, 384 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP (drive), 3rd interface Ethernet PROFINET with 2-port switch, Integr. I/O for technology, Front connector (1x 40-pole) and Micro Memory Card min. 8 MB required
Overview
- SIMATIC CPU with integral technology/motion control functionality
- With full standard CPU 315-2 PN/DP functionality (except for CBA)
- For cross-industry automation tasks in series machine, special machine and plant construction
- Ideal for synchronized motion, such as coupling to a virtual/real master, gear synchronization, cam disk, path interpolation, or print mark compensation
- 3D path interpolation with different kinematics
- Position and pressure-regulated hydraulic axes
- Used as central controller in production lines with central and distributed I/O
- With integrated I/O for high-speed technology functions (e.g. camming, reference point acquisition)
- PROFIBUS DP (DRIVE) interface for isochronous connection of drive components
- PROFINET interface with 2-port switch
- PROFINET IO controller for operating distributed I/O on PROFINET
- One common S7 user program for control and motion control tasks (no additional programming language necessary for motion control)
- “S7 Technology” option package required (version V4.2 SP3 and higher)
SIMATIC Micro Memory Card (8 MB) required for operation of the CPU.
Application
The CPU 315-3 PN/DP is used primarily in machines where a control with a large program memory coincides with high processing speed and motion control requirements, e.g.:
- Processing/assembly lines
- Carton erectors
- Palletizers
- Handling systems
- Flying shears
- Bottling plants
- Wrapping
- Labeling machines
- Roll feeds
- Portals with interpolation
A maximum of 8 axes can be controlled. Along with accurate single axis positioning, the module is suitable primarily for complex motion sequences such as coupling to form a virtual or actual master, gearing, cam, path interpolation or print mark correction.
As a result of its capacity, the CPU 315T-3 PN/DP is ideal for the use of SIMATIC Engineering Tools, e.g.:
- Programming with SCL
- Machining step programming with S7-GRAPH
Design
The CPU 315T-3 PN/DP has the same functionality as the high-performance CPU 315 as well as additional integrated functions for technology/Motion Control. Integrated, fast I/O for technical functions such as output cam switching or home position detection round off the module.
The CPU 315T-3 PN/DP features:
- Microprocessor;
the processor can handle execution times of approx. 0.05 µs per binary instruction and 0.45 µs per floating-point instruction. The CPU 315T-3 PN/DP reaches very high processing speeds, particularly where word or double-word commands and 32 bit fixed-point commands are concerned. - 384 KB work memory (corresponds to approx. 128 K instructions);
the extensive work memory for program components relevant to execution offers sufficient space for user programs. SIMATIC Micro Memory Cards (8 MB) as load memory for the program also allow the project to be stored in the CPU (complete with symbols and comments) and can be used for data archiving and recipe management. - Integrated inputs and outputs
4 digital inputs and 8 digital outputs, can be used for technical functions such as home position detection (BERO) or rapid output cam switching signals.
The digital inputs can also be used (with some restrictions) in the STEP 7 user program. - Flexible expansion possibilities;
max. 8 modules (single-tier configuration) - Combined MPI/DP interface;
The first MPI/DP integrated interface can establish as many as 32 connections simultaneously to S7-300/400 or connections to PG, PC, OP. Among these connections, one is always reserved for programming devices and another for OPs. A simple network with up to 32 CPUs can be configured with the MPI and “global data communication”.
This interface can be reconfigured from an MPI to a PROFIBUS DP interface. The DP interface can be used as a DP master or as a DP slave. - PROFIBUS DP (DRIVE) interface:
The PROFIBUS DP (DRIVE) interface supports isochronous mode and therefore provides an essential requirement to control high-speed and time-critical operations, such as are found in distributed axes in synchronized applications. The interface can only be used as a DP master. It serves to connect drive components. DP-V0 slaves can also be operated on the DP(DRIVE) line on a limited basis in addition to drive systems. The connectable drives are specified in the technical specifications.
A list of the drives that can be operated on the DP-Drive can be found under this link. - PROFINET
The third integral interface of the CPU 315T-3 PN/DP is a PROFINET interface with 2-port switch, based on Ethernet TCP/IP. It supports the following protocols:- S7 communication for data communication between SIMATIC controllers
- PG/OP communication for programming, commissioning and diagnostics through STEP 7
- PG/OP communication for interfacing to HMI and SCADA
- Open TCP/IP, UDP and ISO-on-TCP (RFC1006) communication over PROFINET
- SIMATIC NET OPC server for communication with other controllers and I/O devices with own CPU
Visit 6ES7315-7TJ10-0AB0
For more our products visit turll.com












Reviews
There are no reviews yet.