Overview
- The CPU with a very large program and data memory in the S7-1500 Controller product range for demanding applications with extremely high requirements regarding program scope, performance and networking
- Extremely high processing speed for binary and floating-point arithmetic
- For cross-industry automation tasks in series machine, special machine and plant construction
- Used as central PLC in production lines with central and distributed I/O
- PROFINET IO IRT interface with 2-port switch
- PROFINET IO controller for operating distributed I/O on PROFINET.
- PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under a SIMATIC or non-Siemens PROFINET IO controller
- Two additional PROFINET interfaces with separate IP address; for network separation. The PROFINET interface X2 can be used for connecting additional PROFINET IO RT devices or for fast communication as an I-Device. The PROFINET interface X3 facilitates data transfer at a speed of 1 Gbps.
- PROFIBUS DP master interface
- OPC UA Server and Client as runtime option for the easy connection of SIMATIC S7-1500 to non-Siemens devices/systems with the functions:
- OPC UA Data Access
- OPC UA Security
- OPC UA Methods Call
- Support of OPC UA Companion specifications
- OPC UA Alarms & Conditions
- Central and distributed isochronous mode on PROFIBUS and PROFINET
- Integrated Motion Control functionalities for controlling speed-controlled and positioning axes, support for external encoders, precise position gearing between axes, output cams/cam tracks and probes
- Integrated web server for diagnostics with the option of creating user-defined web pages
Note:
SIMATIC Memory Card required for operation of the CPU
Application
The CPU 1518-4 PN/DP is the fastest S7-1500 CPU with very large program and data memory for demanding tasks in applications that also contain distributed automation structures alongside central I/O. It can be used, for example, as a central controller in production lines or as a machine controller with high processing speed demands.
The CPU 1518-4 PN/DP can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device). The integrated PROFINET IO IRT interface is designed as 2-port switch so that a linear topology can be set up in the system.
Two additional integrated PROFINET interfaces with separate IP address can be used, for example, for network separation. Additional PROFINET IO RT devices can be connected via the PROFINET interface X2 or fast communication can be established in the form of an I-Device. The X3 interface can be used with a transmission rate of 1 Gbit/s, e.g. for communication with the backbone. Distributed I/O can be connected via PROFIBUS via the integrated PROFIBUS interface.
In addition, the CPU offers comprehensive control functionalities as well as the ability to connect drives via standardized PLCopen blocks.
Design
The CPU 1518-4 PN/DP features:
- A powerful processor:
The CPU achieves command execution times as low as 1 ns per binary instruction. - Extensive work memory:
6 MB for program, 60 MB for data - SIMATIC Memory Cards as load memory;
permit additional functions such as datalog and archives - Flexible expansion capability:
Single-tier configuration with max. 32 modules (CPU + 31 modules) - Display with functions for
- Display of overview information such as IP address of the integrated interface, station name, plant designation, location identifier, etc.
- Display and acknowledgment of diagnostic and user messages
- Showing module information
- Showing display settings
- Display of a user-definable logo
- Setting IP addresses
- Setting the date and time
- Selection of operating mode
- Resetting the CPU to factory settings
- Backup and restoration of project
- Disabling/enabling of the display
- Enabling protection levels
- PROFINET IO IRT interface and second PROFINET IO RT interface for connecting distributed I/O via PROFINET
- Three PROFINET interfaces for network separation, for example; PROFINET interface X3 with a data transfer rate of up to 1 Gbps
- PROFIBUS DP interface for connecting distributed I/O via PROFIBUS
Function
- Performance
- Faster command processing, language extensions and new data types depending on the CPU type
- Even shorter response times of the CPUs due to considerably faster backplane bus
- Powerful network connection:
PROFINET IO IRT (2-port switch) as standard interface. Two additional PROFINET interfaces integrated, e.g. for network separation. Additional PROFINET IO RT devices can be connected via the PROFINET interface X2 or fast communication can be established in the form of an I-Device. The X3 interface can be used with a transmission rate of 1 Gbit/s, e.g. for communication with the backbone
- Integrated technology
- Connection of analog and PROFIdrive-capable drives via standardized blocks (PLCopen)
- Support of speed-controlled and positioning axes as well as external encoders, precise position gearing between axes
- Trace functions for all CPU tags, both for diagnostics in real time as well as for sporadic error detection; can also be called via the web server of the CPU
- Comprehensive control functionalities, e.g. easy to configure blocks for automatic optimization of the control parameters for optimum control quality
- Security Integrated
- Password-based know-how protection against unauthorized read-out and modification of program blocks
- Copy protection for tying individual blocks to the serial number of the SIMATIC Memory Card: The block can only run if the configured memory card is inserted in the CPU.
- 4-level authorization concept:
Communication to the HMI devices can also be restricted. - Manipulation protection:
The controller recognizes changed or unauthorized transmissions of the engineering data.
- Design and handling
- Display of overview information:
E.g. Station name, plant identifier, location designation, etc., diagnostic information, module information, display settings. - Possible operations on the display:
Set addresses of the CPU or connected Ethernet communications processors, set date and time, select operating mode of CPU, reset CPU to factory settings, disable/enable display, activate protection levels, acknowledge messages, backup and restoring of the project.
- Display of overview information:
- Integrated system diagnostics
- System diagnostics information is displayed consistently and in plain text in the display, TIA Portal, HMI devices and Web server, even for messages from the drives, and updated even if the CPU is in STOP mode.
- Integrated in the firmware of the CPU, no special configuration is required
- SIMATIC Memory Card (required for operation of the CPU)
- Used as a plug-in load memory or for updating the firmware.
- Also for storing additional documents or csv files (for recipes and archives)
- Creation of data blocks for storage/reading of data via SFCs of the user program
- Datalog (archives) and recipes
- Storage of csv files for recipes and archives on the SIMATIC Memory Card;
easy access to plant-relevant operating data using Office tools or via a web server - Easy access to configuration data of the machine by means of a Web browser or SD card reader (two-way data exchange from and to the controller)
- Storage of csv files for recipes and archives on the SIMATIC Memory Card;
- Programming
- Programming with STEP 7 Professional, V13 and higher
- Migration tool for migrating from SIMATIC S7-300/S7-400 to S7-1500; converts the program code largely automatically. Non-convertible code is logged and can be manually adapted.
- S7-1200 basic programs can be transferred to S7-1500 by copy-paste.